Back to results

University of Washington

High-Voltage Compliant, Electrode-Invariant Neural Stimulation Electronics Compatible with Low-Voltage, Bulk-CMOS Integration

Abstract

dc:description.abstract

This work explores the challenges of implementing practical, electrical neural stimulation interfaces using modern silicon CMOS technologies. To overcome said challenges, which stem from the discrepancy between the low-voltage limitations of modern CMOS devices and the large stimulation voltages often observed at response-evoking stimulus levels, a new stimulator front-end is proposed. The high-voltage compliant front-end can reliably drive biphasic, constant-current stimulus through a wide range of electrode impedances while being safely implemented in a low-voltage, bulk-CMOS technology. The topology of the front-end is based on a sink-regulated H-bridge. Stimulus current is supplied using specialized, fully-integrated dynamic voltage supplies (DVSs), which are controlled in closed-loop to have an output voltage approximately equal to the voltage of the electrode each supplies stimulus to. The entire stimulus waveform is regulated by a single, low-voltage current-DAC, which can safely interface with the electrodes (which may be at high voltages) via specialized high-voltage adapter (HVA) circuits. To account for “capacitive-looking” electrodes and to provide unique, “electrode-invariant” performance, the front-end uses the balancing stimulus current to discharge the electrode-tissue-interface impedance (ZE), and only after full ZE discharge has been detected is a DVS used to supply the remaining balancing stimulus. In this thesis the described front-end topology and the enabling high-voltage operating circuits are presented and discussed in detail. Additionally, a stand-alone DVS circuit has been fabricated in 65nm bulk-CMOS, demonstrating the power-supplying and transient performance required by the proposed stimulator design. Another chip, featuring the entire integrated neural stimulator front-end, has also been designed in 65nm bulk-CMOS, with post-layout simulations showing ±11V compliance (approximately) across a 50μA to 2mA stimulus amplitude range. The efficacy of the proposed integrated electronics in potential neural stimulation applications is also explored using a board-level prototype and in-vivo evaluation.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pepin, Eric Philip
Advisor dc:contributor.advisor
  • Rudell, Jacques C

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the individual authors.
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1773/33811
OAI identifier oai:identifier
oai:digital.lib.washington.edu:1773/33811

Chain of custody

source
Harvested from
University of Washington
Base URL
digital.lib.washington.edu/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Pepin, Eric Philip. High-Voltage Compliant, Electrode-Invariant Neural Stimulation Electronics Compatible with Low-Voltage, Bulk-CMOS Integration. 2015. http://hdl.handle.net/1773/33811