Virginia Tech
Using Accelerometers to Quantify Infant General Movements as a Tool for Assessing Motility to Assist in Making a Diagnosis of Cerebral Palsy
Abstract
dc:description.abstractQuantitative approaches to directly measure infant movement have not utilized miniature electronics technology, nor been used effectively in evaluating neurological dysfunctions' affect on movement. This thesis presents a new quantitative technique for measuring infant general movements (GMs) using micro-electromechanical accelerometers, while discussing future improvements for this technology and possible benefits to present methods of diagnosing cerebral palsy. For decades, GMs have interested neurologists because characteristics can indicate neurological dysfunctions. Motions over the entire body that show fluency, variation, and complexity characterize normal GMs. Analyzing these movements can accurately predict neurological dysfunction - cerebral palsy, in particular. This research describes a technique to make consistent, quantitative measurements of GMs using accelerometers on infant limbs. Signal processing techniques can find patterns, later determined characteristic of neurological dysfunctions. Such analyses complement the current technique of video footage review. Additionally, data could be reanalyzed using updated signal processing algorithms. An accurate collection of data allows physicians to quickly review an infant's entire history of motion studies. Physical information can be inferred from the data. Correlation techniques have compared motions from different limbs to examine coordination. Evidence suggests this may help indicate dysfunction. High-speed data acquisition enables the study of high-frequency motions, possibly undetectable with the human eye. This research has successfully recorded acceleration and video during GMs from four limbs on multiple infants. Signal processing techniques have been applied to create various graphical representations. The direct measurement of movement makes this work unique, enabling a graphical analysis tool for physicians based on physical performance.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Department dc:contributor.department
- Mechanical Engineering
- Grantor dc:publisher
- Virginia Tech
- Year dc:date.issued
- 2003
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Conover, Mark Stuart
- Chair dc:contributor.committeechair
-
- Wicks, Alfred L.
- Committee members dc:contributor.committeemember
-
- Robertshaw, Harry H.
- Peck, Dawn H.
Subjects
dc:subject × 6Rights
dc:rights- Statement dc:rights
-
- In Copyright
- Licence dc:rights.uri
Identifiers
dc:identifier.*- Dc Identifier Other
- etd-09232003-153717
- OAI identifier oai:identifier
- oai:vtechworks.lib.vt.edu:10919/35157