Back to results

University of Illinois at Urbana-Champaign

SHA-less pipeline ADC design with sampling clock skew calibration

Abstract

dc:description

The power efficiency of pipeline analog-to-digital converters (ADCs) can be substantially improved by eliminating the front-end sample-and-hold amplifier (SHA). However, in a SHA-less architecture the sampling clock skew between the sub-ADC and the multiplying digital-to-analog converter (MDAC) in the pipeline first stage results in gross conversion errors at high input frequencies. This skew effect is aggravated in a SHA-less multi-bit-per-stage pipeline architecture, where the built-in redundancy is limited. Sampling clock skew is an essential problem in SHA-less pipeline ADCs that prohibits their use at high input frequency applications. In this thesis, a mostly digital background calibration technique is developed to remove the sampling clock skew in SHA-less pipeline ADCs. The skew information is extracted from the first-stage residue output with two comparators sensing out-of-range errors; a gradient-descent algorithm is used to adaptively adjust the timing of the sub-ADC to synchronize with that of the sample-and-hold (S/H) in the MDAC. A prototype 10-bit, 100-MS/s SHA-less pipeline ADC incorporating this calibration technique was designed and fabricated in 90-nm CMOS process. The prototype ADC converts from DC to the 12th Nyquist band with a 3.5-bit front-end stage. It digitizes inputs up to 610 MHz without skew errors in experiments; in contrast, the same ADC fails at 130 MHz with calibration disabled. The calibration circuits were fully integrated on chip. The ADC consumes 12.2 mW and occupies 0.26-mm2 silicon area, while the calibration circuits dissipate 0.9 mW and occupy 0.01 mm2. A 71-dB spurious-free dynamic range (SFDR) and a 55-dB signal-to-noise-and-distortion ratio (SNDR) were measured with a 20-MHz sine-wave input, and a larger than 55-dB SFDR was measured in the 10th Nyquist band.

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Electrical & Computer Engr
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Huang, Pingli
Contributors dc:contributor
  • Chiu, Yun
  • Feng, Milton
  • Rosenbaum, Elyse
  • Wong, Martin D.F.

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • COPYRIGHT 2011 PINGLI HUANG
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/29565
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/29565

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Huang, Pingli. SHA-less pipeline ADC design with sampling clock skew calibration. Dissertation thesis, University of Illinois at Urbana-Champaign, 2012. http://hdl.handle.net/2142/29565