Back to search

University of Illinois at Urbana-Champaign

Evaluation of self-contained breathing apparatus (SCBA) design and weight on firefighter physiological and biomechanical response

Abstract

dc:description

Firefighters wear personal protective equipment to protect them from the thermal and chemical environment in which they must operate to perform fire suppression activities. Specifically, the self-contained breathing apparatus (SCBA), which is worn on the back and contains compressed air, provides isolation to the airway from the hazardous fireground. The weight of the SCBA can induce changes in the firefighter’s balance and when combined with physically demanding work can increase the physiological and metabolic response of the firefighter. Current national standards limit the weight of the SCBA to 16kg. However, new technologies exist that could be of value to the firefighter and could be integrated into the SCBA but may increase the weight above the existing limit. The study within this dissertation seeks to examine the effects on the physiological response, dynamic stability, and comfort of increased self-contained breathing apparatus weight in active firefighters within the United States Fire Service. As in previous studies, completion of firefighting activities induced a high physiological and metabolic response, though these measures showed few differences between SCBA weighing 16kg, 18.3kg, and 20.5kg. There was a trend toward statistical significance for time the participant was able to perform firefighting activities prior to reaching volitional fatigue. Careful consideration should be made when considering raising the existing limits on SCBA weight to avoid negative impacts on firefighting working time and the negative perceptions firefighters felt about the mobility and difficulty in using heavier SCBA.

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Kinesiology
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Kesler, Richard M
Contributors dc:contributor
  • Burd, Nicholas A
  • Wilund, Kenneth
  • Allen, Jacob
  • Horn, Gavin P

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • Copyright 2022 Richard Kesler
Language dc:language
en, eng

Identifiers

dc:identifier.*
Handle dc:identifier
https://hdl.handle.net/2142/117656

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Kesler, Richard M. Evaluation of self-contained breathing apparatus (SCBA) design and weight on firefighter physiological and biomechanical response. Dissertation thesis, University of Illinois at Urbana-Champaign, 2022. https://hdl.handle.net/2142/117656