Back to results

University of Illinois at Urbana-Champaign

Beyond PWM: Active balancing, start-up and ZVS for multi-level converters with applications in renewable energy systems

Abstract

dc:description

This dissertation addresses many of the operational challenges of flying capacitor multi-level (FCML) converters and introduces new techniques to improve performance. First, start-up and a new method to extract power from within an FCML converter at a naturally occurring low-voltage node are investigated with a 5-level FCML converter. The introduction of the auxiliary power supplied induces an undesirable imbalance in the flying capacitors, which increases switch stress and induces additional harmonics in the output current. To reduce the induced imbalance, active balancing is implemented with a single voltage measurement of one specific flying capacitor. To correct for flying capacitor imbalance for more generic conditions, valley current detection has previously been proposed. However, prior work did not account for light load conditions, which we show to be challenging for traditional duty cycle compensation. Here we derive the light load conditions that lead to instability, and propose a new constant effective duty cycle compensation method for active balancing across the full load range. The effectiveness of the method is successfully demonstrated on a 4-level FCML prototype in light load and full load conditions. Quasi square wave zero voltage switching (ZVS) reduces switching losses and has been demonstrated at specific duty cycles for FCML converters in prior work. Here, we derive the fundamental limitations imposed by the FCML topology and show how the ZVS operating range can be extended through specific design choices. The results are demonstrated on an experimental 4-level hardware prototype, achieving step-down operation with a 1 kVdc input. The 4-level prototype also serves as an early stage proof of concept for high-voltage operation with 650 V GaN switches, as previous FCML designs utilized a higher number of FCML levels with lower voltage rated switches. As a final application of these techniques, a 1.5 kV, 15 kW, 3-phase solar photovoltaic (PV) inverter has been designed and implemented. The 5-level converter achieves a peak efficiency of 98.5% and demonstrates 3-phase operation with a Total Harmonic Distortion (THD) of less than 0.25%.

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Electrical & Computer Engr
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stillwell, Andrew
Contributors dc:contributor
  • Pilawa-Podgurski, Robert C. N.
  • Krein, Phillip T
  • Dominguez-Garcia, Alejandro
  • Miljkovic, Nenad

Subjects

dc:subject × 8

Rights

dc:rights
Statement dc:rights
  • Copyright 2019 Andrew Stillwell
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/105675
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/105675

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Stillwell, Andrew. Beyond PWM: Active balancing, start-up and ZVS for multi-level converters with applications in renewable energy systems. Dissertation thesis, University of Illinois at Urbana-Champaign, 2019. http://hdl.handle.net/2142/105675