Reykjavík University
Structural modelling and earthquake analysis of a hospital building located within the Tjörnes fracture zone in Iceland
Abstract
dc:description.abstractThe Tjörnes fracture zone(TFZ)is one of the two most active seismic regions in Iceland. It is of vital importance for civil protection and security of the local residents living in that area to have a fully functioning hospital close by, when a major earthquake event occurs within the TFZ. The main focus of this study is to examine the structural characteristics, dynamic behaviour and structural integrity of the hospital in the town of Húsavik in North Iceland. A structural monitoring system was installed in the building in May 2015. The structural monitoring system is a part of the multidisciplinary strong motion array,ICEARRAY II, which is in operation in North Iceland. The measurements have been ongoing for one year and three notable events have occurred that provide useful full-scale records of the building excitation and response and which have been used to determine key dynamic properties and response characteristics as well as for validation of the structural model. A finite element model was constructed using the structural design software Sap2000 (www.csiberkeley.com). The first natural frequency of the building is 7.4 Hz, and the damping ratio at low intensity excitation was found to be of the order, 2 - 3% of critical. Building codes and standard civil engineering practises have evolved considerably since the construction of the hospital in 1964. Especially with regard to seismic design requirements. Individual building components and structural design details will be examined with this in mind. The earthquake excitation used for the analysis is the EN1998-1 Response spectra and records of strong ground motion from earthquake events that occurred in the South Iceland seismic zone in June 2000 and May 2008. The building has many load carrying walls, in a structural system that provides a lot of redundancy. The building deformations are found to be small, or 1 cm or less for a design response spectral analysis. The same can be said about the story drift which is found to be well within the limits prescribed by EN1998. Structural verification of selected cross sections was performed using M-N interaction diagram and shear capacity calculations according to EN 1992-1. The cross sections resist the interaction between axial force and bending moment but the shear capacity is not satisfactory for earthquake excitation. Concrete stresses are generally found to be low. The density ratio of walls compared to the floor area was calculated to be 7% total experiments have shown that this is a indicator of a good seismic performance.
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Höskuldur Þorbjargarson 1987-
- Contributors dc:contributor
-
- Háskólinn í Reykjavík
Subjects
dc:subject × 9Rights
- Language dc:language.iso
- is
Identifiers
dc:identifier.*- Handle dc:identifier.uri
- http://hdl.handle.net/1946/25604
- OAI identifier oai:identifier
- oai:skemman.is:1946/25604