Back to results

Division of Radiology

Assessment of the interobserver and the intra observer reproducibility for the detection of renal cortical defects in adults and children using [99mtc]Tc-MAG3

Abstract

dc:description.abstract

Objectives: One can assess cortical defects on the early images of [99mTc]Tc-MAG3 renography. We aim to assess interobserver and intraobserver reproducibility for detecting renal cortical defects using [ 99mTc]Tc-MAG3 for adults and children; identify causes for poor inter- and intraobserver reproducibility and to assess the effect of the kidney to background ratio (KTBR) on reproducibility. Methods: A 100 adult and 200 paediatric renograms were included. The observers reviewed the summed 1- min posterior images for the first four minutes to detect cortical defects. Interobserver reproducibility between three observers and intra-observer reproducibility for two observers were determined. Agreement was tested using percentage agreement, Krippendorff's reliability coefficient alpha and Cohen's kappa statistic. The association between KTBR and agreement was assessed. Results: Interobserver agreement on the 1-2 minute images was 78 (95% CI: 74.8 - 82.7%) and 79.7 (95% CI: 75.9 - 83.5%) for left and right kidneys respectively. Intraobserver percentage was 89.7% (95% CI: 86.2 - 93.1%) for the senior and 80.7% (95% CI: 76.2 - 85.2%) for the junior observer. In 13.5% (27) of the adult and 4.5% (19) of the paediatric kidneys the difference in image interpretation between the observers would have had a clinical impact. If the KTBR is ≤ 2, the percentage agreement was between 61.5% and 64.8%. In cases with a KTBR > 2, the percentage agreement was between 83.6% and 87.1%. Conclusion: The percentage interobserver agreement was moderate. Disagreement between normal and abnormal cases were infrequent. The interobserver reproducibility was decreased when the KTBR was ≤ 2.

Degree

thesis:*
Grantor
Division of Radiology
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hashlan, Mohammed Hussain
Advisor dc:contributor.advisor
  • Brink, Anita

Subjects

dc:subject × 1

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/11427/37397
OAI identifier oai:identifier
oai:open.uct.ac.za:11427/37397

Chain of custody

source
Harvested from
University of Cape Town
Base URL
open.uct.ac.za/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Hashlan, Mohammed Hussain. Assessment of the interobserver and the intra observer reproducibility for the detection of renal cortical defects in adults and children using [99mtc]Tc-MAG3. Division of Radiology, 2022. http://hdl.handle.net/11427/37397