Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 35 for “"Interobserver"”.

  1. Interobserver Reliability in the Diagnosis of Pulpal and Periradicular Disease

    The purpose of this study was evaluate the interobserver reliability of endodontists in the diagnosis the presence or absence of pulpal and/or periradicular disease. The study used 47 patients presenting to the VCU School of Dentistry for screening appointments as a test population under the rules …

    vcu Repository record for Interobserver Reliability in the Diagnosis of Pulpal and Periradicular Disease (opens in a new tab)

  2. Assessment of the interobserver and the intra observer reproducibility for the detection of renal cortical defects in adults and children using [99mtc]Tc-MAG3

    … of [99mTc]Tc-MAG3 renography. We aim to assess interobserver and intraobserver reproducibility for detecting renal cortical defects using [ 99mTc]Tc-MAG3 for adults and children; identify causes for poor inter- and intraobserver reproducibility and to assess the effect of the kidney to …

    cape-town Repository record for Assessment of the interobserver and the intra observer reproducibility for the detection of renal cortical defects in adults and children using [99mtc]Tc-MAG3 (opens in a new tab)

  3. Radiographic Union Score for Tibia (RUST) scoring system in adult diaphyseal femoral fractures treated with intramedullary nailing: an assessment of interobserver and intraobserver reliability

    … scored by three reviewers using the RUST system. Interobserver reliability was measured at initial scoring. The 60 sets of radiographs were scored again by the three reviewers to calculate the intraobserver reliability. Results The RUST scores ranged from 4 to 12 with a mean score of 11.3 ± 1.3. …

    cape-town Repository record for Radiographic Union Score for Tibia (RUST) scoring system in adult diaphyseal femoral fractures treated with intramedullary nailing: an assessment of interobserver and intraobserver reliability (opens in a new tab)

  4. Criteri di valutazione medico-legale della narcolessia

    … severity is still lacking. We explored: 1. the interobserver reliability among Italian Medical Commissions making disability and handicap benefit decisions for people with narcolepsy, searching for correlations between the recognized disability degree and patients’ features; 2. the willingness …

    bologna Repository record for Criteri di valutazione medico-legale della narcolessia (opens in a new tab)

  5. Perspectives on the management of humerus fractures due to gunshot trauma: an inter- and intra-observer agreement and reliability study

    … on gunshots of the humerus were available. Interobserver agreement studies reported low levels of intra- and inter-rater reliability (IRR) for the classification of proximal humerus fractures using Neer and AO/OTA classification. The complexity of the fractures, the inconsistency of …

    cape-town Repository record for Perspectives on the management of humerus fractures due to gunshot trauma: an inter- and intra-observer agreement and reliability study (opens in a new tab)

  6. Stability and Robustness of Radiomic Features Due to Volumetric Uncertainty in Pancreatic Cancer

    … in segmentation between observers lead to interobserver variability and is a known phenomenon. Some studies have investigated such effects for a few cancer sites such as lung, brain, breast, and prostate. However, tumor delineation uncertainty highly depends on the tumor site, and …

    creighton Repository record for Stability and Robustness of Radiomic Features Due to Volumetric Uncertainty in Pancreatic Cancer (opens in a new tab)

  7. An Analysis of Select Psychometric Properties of the Vocational Assessment and Curriculum Guide

    … of measurement, internal consistency, and interobserver agreement were examined. A validation procedure was conducted to determine whether VACG domain scores discriminated between subject groups with different employment characteristics.

    uiuc Repository record for An Analysis of Select Psychometric Properties of the Vocational Assessment and Curriculum Guide (opens in a new tab)

  8. Echocardiographic evaluation of horses challenged with African horse sickness virus

    … the eFoCUS evaluation substantial and perfect interobserver agreement were found for an increase in myocardial thickness and diminution of the left ventricle, respectively, suggesting that these variables could be used to subjectively evaluate intravascular volume in clinical cases in an …

    pretoria Repository record for Echocardiographic evaluation of horses challenged with African horse sickness virus (opens in a new tab)

  9. Implementation,Validation and Application of an Automated Motion Correction Algorithm in Hepatic Perfusion CT for Image-Guided Radiotherapy

    … and standard contrast enhanced 4D-CT scans. Interobserver concordance was used as surrogate for accuracy. Knowledge of contrast kinetics from DCE-CT scans was also applied to model contrast enhancement in radiotherapy alignment cone-beam CT. Contrast enhanced cone-beam CT scans were acquired …

    uwo Repository record for Implementation,Validation and Application of an Automated Motion Correction Algorithm in Hepatic Perfusion CT for Image-Guided Radiotherapy (opens in a new tab)

  10. Self-regulation to practice: Incorporating the strategy to an early childhood special education setting

    … impact of the treatment package was studied. Interobserver agreement (IOA) was used to determine accuracy to self-identify behaviors. Results indicated a student increase in identifying undesired and desired behaviors, the percentage of desired behaviors displayed, and the accuracy with …

    purdue-thes Repository record for Self-regulation to practice: Incorporating the strategy to an early childhood special education setting (opens in a new tab)

  11. Automatic Burns Analysis Using Machine Learning

    … diagnosing burn injuries, but it suffers from interobserver variability and is not suitable for intermediate burn depths. To address these challenges, machine learning-based techniques were proposed to evaluate burn wounds in a thesis. The study utilized image-based networks to analyze two …

    bradford Repository record for Automatic Burns Analysis Using Machine Learning (opens in a new tab)

  12. Hochaufgelöste cine-Magnetresonanz-Bildgebung des Mäuseherzens zur Bestimmung rechtsventrikulärer Morphologie und funktioneller Parameter : Validierung der Methode und Etablierung an zwei Modellen der Herzinsuffizienz

    … Maß an Reproduzierbarkeit (intraobserver- und interobserver-Variabilität jeweils <7%). Die MR-Messung 4 Wochen nach Pulmonalbanding ergab einen signifikanten Anstieg des RV enddiastolischen Volumens (+44%, p<0.005) und vor allem RV endsystolischen Volumens (+133%, p<0.0001). Die RV …

    wurz-thes Repository record for Hochaufgelöste cine-Magnetresonanz-Bildgebung des Mäuseherzens zur Bestimmung rechtsventrikulärer Morphologie und funktioneller Parameter : Validierung der Methode und Etablierung an zwei Modellen der Herzinsuffizienz (opens in a new tab)

  13. Analyzing the Consistency of Scoring Porotic Hyperostosis From 3D Scans

    … scans on three separate days. Intraobserver and interobserver error tests were performed to determine if there were any patterns in the researchers’ scores. In addition, the data for each of the 25 scans were examined to determine if the quality of the scans influenced the consistency of the …

    usm Repository record for Analyzing the Consistency of Scoring Porotic Hyperostosis From 3D Scans (opens in a new tab)

  14. Do anatomical contoured plates address scapula body, neck, and glenoid fractures and can these fractures be classified? – A multi-observer consensus study

    … in plate design is required. Good to moderate interobserver reliability were observed using the Ideberg fracture classification for intra-articular fractures and the AO/OTA classification for extraarticular fractures involving the body.

    cape-town Repository record for Do anatomical contoured plates address scapula body, neck, and glenoid fractures and can these fractures be classified? – A multi-observer consensus study (opens in a new tab)

  15. Application and Evaluation of Teledermatology In An Underserved Area of Honduras

    … were the types of dermatologic conditions, interobserver agreement, image quality, and patient and physician satisfaction. The findings of this study substantiate the need for dermatologic care, as approximately 1 out of every 5 patients of the JMA Clinic presented with a dermatologic …

    vt Repository record for Application and Evaluation of Teledermatology In An Underserved Area of Honduras (opens in a new tab)

  16. Corpus callosum morphology in children on mid-sagittal MR imaging

    … tabulation with the chi-square test and ANOVA. Interobserver correlation was assessed using Kappa coefficient of conformance. Results: 257 patients with mean age 72±60 months were included, 142 were male (55%). In abnormal MRI’s the CC was less likely to have an identifiable isthmus and was more …

    cape-town Repository record for Corpus callosum morphology in children on mid-sagittal MR imaging (opens in a new tab)

  17. Panoramic Radiographic Diagnosis of Molar-Incisor Hypomineralization in Permanent Dentition

    … predictive values, total agreement, and interobserver agreement were analyzed. Results: Radiographic signs suggestive of MIH were more frequently identified in erupted teeth at advanced developmental stages and in lesions involving multiple tooth surfaces. Significant associations were …

    uic

  18. Quantitative Untersuchungen zur Biometrie des vorderen Augenabschnittes

    … eine deutliche Schwäche bezüglich der Interobserver-Reproduzierbarkeit festzustellen, dies ließe sich durch eine exaktere Meßpunktdefinition sicherlich noch verbessern. Dies ist auch erforderlich zur Verlaufsbeurteilung pathologischer Prozesse. Auch der Akkomodationszustand stellt eine …

    wurz-thes Repository record for Quantitative Untersuchungen zur Biometrie des vorderen Augenabschnittes (opens in a new tab)

  19. Secundum atrial septal defect in the adult. Clinical, haemodynamic and electrophysiological aspects.

    … and repeatability showed a difference of 1±5%. Interobserver variability was four times higher for radionuclide angiography than MRvm, 16% vs. 4%, demonstrating the superiority of MRvm. Atrial electrophysiological properties before and 8±6 months after ASD closure were examined by means of …

    lund Repository record for Secundum atrial septal defect in the adult. Clinical, haemodynamic and electrophysiological aspects. (opens in a new tab)

Page 1 of 2