Back to results

University of Cambridge

Miniaturisation of pH Holographic Sensors for Nano-Bioreactors

Abstract

dc:description.abstract

Monitoring and controlling pH is of utmost importance in bioprocessing as it directly affects product yield and quality. Multiplexed experiments can be performed in nanobioreactors for optimisation of yield and cell heterogeneity in a relatively quick and inexpensive manner. In this thesis, a pH holographic sensor (holosensor) is miniaturised to 3.11 nL in volume and integrated into a PDMS-glass microfluidic chip for monitoring the growth of Lactobacillus casei Shirota. Although other established methods for monitoring cell cultures can be utilised, miniaturised holosensors enable real-time and non-consumptive monitoring of the bacterial cell culture growth medium. The 2-hydroxyethylmethacrylate (HEMA)-co-2-(trifluoromethyl) propenoic acid (TFMPA) holosensor was fabricated using an adapted technique from photolithography, coupled with the use of a polymerisation inhibitor to control the gel polymerisation with diameters not exceeding a standard deviation of 0.067. The hologram brightness was optimised to 1.05 ms integration time with 36X magnification using a low power (0.290 mW) 532 nm green continuous wave (CW) laser with a devised beam-offset technique. The holosensor was characterised with ionic strength balanced (9.50 mS/cm) McIIvaine pH buffers and a calibration curve plotted together with measured ionic strength, optical density at 600 nm (OD600) and pH. Correspondingly, RGB-xyY transformed values were plotted in the CIE 1931 chromaticity diagram. Later, a miniaturised 0.4$\phi$ HEMA-co-TFMPA holosensor and array was also demonstrated. Together with the 3.0$\phi$ holosensor, an accuracy parameter for the 0.4$\phi$ spot and array holosensors were calculated to be 99.08%, 99.38% and 97.77% respectively. Further work involved studying the issues associated with fabricating gels with unusually flat gel profiles. Other preliminary results suggested the alternative of utilising polymers as a holosensor substrate, together with a dye-free method for hologram fabrication, outlined the prospective possibility of a miniaturised holosensor integrated into a polymer microfluidic chip with the flexibility of hologram colour customisation for cell culture monitoring.

Degree

thesis:*
Name dc:type.qualificationname
Doctor of Philosophy (PhD)
Level dc:type.qualificationlevel
Doctoral
Grantor dc:publisher.institution
University of Cambridge
Year dc:date.issued
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Chan, Leon, Cong Zhi
Advisor dc:contributor.advisor
  • Lowe, Christopher R

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Permission was granted for figures utilised in this thesis and acknowledgement was provided in the figure captions as stipulated by the figures copyright owners.
Language dc:language
en

Identifiers

dc:identifier.*
Author Identifier
0000-0001-7712-1060
OAI identifier oai:identifier
oai:www.repository.cam.ac.uk:1810/268167

Chain of custody

source
Harvested from
Cambridge University
Base URL
api.repository.cam.ac.uk/server/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Chan, Leon, Cong Zhi. Miniaturisation of pH Holographic Sensors for Nano-Bioreactors. Doctoral thesis, University of Cambridge, 2017. https://doi.org/10.17863/CAM.14368