Investigation of the prevalence of opportunistic gram negative pathogens in the water supply of a haematology unit, and the application of point-of-use filtration as an intervention.

Abstract

dc:description.abstract

Gram-negative infection has been linked to hospital water although few studies have examined whether water systems are reservoirs of nosocomial pathogens. This study investigated longitudinal recovery of the opportunistic pathogens Pseudomonas aeruginosa, Stenotrophomonas maltophilia and Acinetobacter baumannii from water outlets of a haematology unit and evaluated Point-Of-Use Filtration (POU-F) as a control measure. In a two-year double cross-over trial, water samples and swabs were taken weekly from 39 showers/taps on the unit. Four study phases alternated between non-filtered (Phases 1 & 3), and filtered outlets (Phases 2 & 4) using Pall AquasafeTM 14-day filters. In Phases 1 & 3; 99% of 1396 samples yielded bacterial growth, with colonies generally too numerous to count. Target species were isolated from 22% of water samples (P. aeruginosa 14%; S. maltophilia 10%) and 10% of swabs. P. aeruginosa was particularly associated with handwash stations and S. maltophilia with showers. A. baumannii was not isolated. With POU-F; 22% of 1242 samples yielded bacterial growth (mean CFU/100ml ,4.6). S. maltophilia was isolated only once from water but never from outlet swabs. PCR typing identified clusters of isolates colonizing different outlets over time but no clear association between water and patient isolates was identified. The incidence of Gram negative infections remained low throughout the study. Without POU-F, water from taps/showers represented a source of bacteria including the target species. POU-F substantially reduced the frequency and number of target species from every outlet, and merits further investigation as an intervention to protect immunocompromised patients from opportunistic pathogens.

Degree

thesis:*
Grantor dc:publisher.institution
University of Bradford
Year dc:date.issued
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Wright, Claire Louise
Advisor dc:contributor.advisor
  • Snelling, Anna M.

Subjects

dc:subject × 12

Rights

dc:rights
Statement dc:rights
  • <a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/"><img alt="Creative Commons License" style="border-width:0" src="http://i.creativecommons.org/l/by-nc-nd/3.0/88x31.png" /></a><br />The University of Bradford theses are licenced under a <a rel="license" href="http://creativecommons.org/licenses/by-nc-nd/3.0/">Creative Commons Licence</a>.
Language dc:language.iso
en

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/10454/5692
OAI identifier oai:identifier
oai:bradscholars.brad.ac.uk:10454/5692

Chain of custody

source
Harvested from
University of Bradford
Base URL
bradscholars.brad.ac.uk/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Wright, Claire Louise. Investigation of the prevalence of opportunistic gram negative pathogens in the water supply of a haematology unit, and the application of point-of-use filtration as an intervention.. University of Bradford, 2013. http://hdl.handle.net/10454/5692