Back to results

University of York

Microfluidic cancer cell isolation system using magnetic nanoparticle hybrids and advanced interdigitated electrode technology

Abstract

dc:description.abstract

For the past decade in the biomedical engineering industry, extensive research has been conducted in improving magnetic sensing technologies for cell isolation systems. These technologies, through the popular biomarkers, i.e. DNA, RNA, proteins, antibodies, have already been implemented in clinical diagnosis and/or prognosis.An example of a successful commercial product is Invitrogen’s Dynabeads® Technology. Magnetic cell isolation technologies have been evolving slowly mainly due to the complexity of the cancers, the short number of successful cancer biomarkers, and the ethics of magnetic nanoparticles in in-vivo cancer therapy. However, in-vitro cancer therapy is becoming attractive. This thesis explains the research and development of a microfluidic cancer cell isolation system, which together magnetically separates and destroys cancer cells through hyperthermia of MWNTs. The full year was been spent on literature review, designing the microfluidic system, training fabrication and characterization techniques, fabricating component 1 through photolithography, and characterizing surface smoothness and height variation, through atomic force microscopy, and confirming size specifications and detecting electrode rigidity, through scanning electron microscopy. The project is currently being patented due to the uniqueness of the in-vitro cancer therapy concept. AFM confirmed the electrode heights to be approximately 25 nm ± 3 nm, for all three samples, and random variations of surface electrode smoothness from ± 5-10 nm. This concluded how the uneven distribution of SiO2 layer affected the height and smoothness of the electrodes. SEM confirmed decent size specifications for mask design 2 and 5, as they followed the desired size specifications in the design process. However, mask design 4 ended up with electrodes, twice the width of the desired size, that could have been a result of diffraction or mask complexity which thereafter affected the evaporated material.

Degree

thesis:*
Name dc:type.qualificationname
M.Sc by research
Level dc:type.qualificationlevel
masters
Grantor dc:publisher.institution
University of York
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Mahendru, Dishant
Advisor dc:contributor.advisor
  • Xu, Yongbing

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Mahendru, Dishant. Microfluidic cancer cell isolation system using magnetic nanoparticle hybrids and advanced interdigitated electrode technology. masters thesis, University of York, 2010.