Back to results

University of Leeds

Joint contact modelling of articular cartilage in synovial joints

Abstract

dc:description.abstract

Hip joint is one of the important load bearing joints and has been extensively studied to investigate contact mechanics and tribology. It has known to experience high contact forces and stresses. However, cartilage shows remarkable lubricating and wear properties, and survives the lifetime of a person. Biphasic lubrication based on the principle of fluid load support has provided an explanation for this. However, when, the cartilage fails the part or whole of the joint needs to be replaced and hemiarthroplasty is one such remedy. Three-dimensional finite element models with elastic/hyperelastic cartilage have been used to investigate contact mechanics of the hip joint. However, to understand the role of interstitial fluid in contact mechanics and tribology, cartilage has to be modelled as biphasic material. Interventions such as hemiarthroplasty may alter this phenomenon and hence it is also important to know the extent of this effect. This study was thus an attempt to address these issues. An algorithm developed earlier for 2-D problems was refined, adapted and tested for 3-D problems to detect nodes in contact to impose surface fluid flow conditions. This was then used in natural hip joint where fluid load support was found to be very high (~94%). Three-dimensional hemiarthroplasty was then experimentally verified using porcine hips. The methodology was then used to investigate the effect of clearance in hemiarthroplasty which confirmed the earlier findings that undersizing of the femoral head increases both contact and shear stresses probably leading to cartilage erosion. The investigation of the activities of daily living showed lower contact stresses when compared to the outcomes of clinical studies and depended not only on the magnitude of the load but also on their locations. In all the models the total fluid load support was very high and was between ~90% which supported the biphasic lubrication hypothesis.

Degree

thesis:*
Name dc:type.qualificationname
Ph.D
Level dc:type.qualificationlevel
doctoral
Grantor dc:publisher.institution
University of Leeds
Year dc:date.issued
2010

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pawaskar, Sainath Shrikant
Advisors dc:contributor.advisor
  • Jin, Z.
  • Ingham, E.
  • Fisher, J.

Identifiers

dc:identifier.*
Identifier
uk.bl.ethos.520416
OAI identifier oai:identifier
oai:etheses.whiterose.ac.uk:1025

Chain of custody

source
Harvested from
White Rose University Consortium
Base URL
etheses.whiterose.ac.uk/cgi/oai2
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Pawaskar, Sainath Shrikant. Joint contact modelling of articular cartilage in synovial joints. doctoral thesis, University of Leeds, 2010.