Back to results

University of the Western Cape

Cytochrome C biosensor for the determination of trace level arsenic and cyanide compounds

Abstract

dc:description.abstract

In this work, an electrochemical method based on a cyt c biosensor has been developed, for the detection of selected arsenic and cyanide compounds. Boron Doped Diamond (BDD) electrode was used as a transducer, onto which cyt c was immobilised and used for direct determination of Prussian blue, potassium cyanide and arsenic trioxide by inhibition mechanism. The sensitivity as calculated from cyclic voltammetry (CV) and square wave voltammetry (SWV), for each analyte in phosphate buffer (pH= 7) was found to be (1.087- 4.488 ×10-9 M) and the detection limits ranging from 0.0043- 9.1 μM. These values represent a big improvement over the current Environmental Protection Agency (EPA) and World Health Organisation (WHO) guidelines.

Degree

thesis:*
Grantor dc:publisher.institution
University of the Western Cape
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Fuku, Xolile Godfrey
Advisors dc:contributor.advisor
  • Baker, Priscilla G.L.
  • Iwuoha, Emmanuel

Subjects

dc:subject × 16

Chain of custody

source
Harvested from
University of the Western Cape
Base URL
uwcscholar.uwc.ac.za:8443/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Fuku, Xolile Godfrey. Cytochrome C biosensor for the determination of trace level arsenic and cyanide compounds. University of the Western Cape, 2011.