Back to results

University of Washington

CE-microreactor-CE-MS-MS for protein analysis

Abstract

dc:description.abstract

Capillary electrophoresis-mass spectrometry (CE-MS) provides a powerful system that combines the speed and automation capabilities of CE with the detection and identification capabilities of MS. Integrating on-line enzymatic microreactor digestion with a CE-MS system reduces sample handling and allows fast digestions of small protein samples.In this thesis work, an on-line CE-microreactor-CE-MS-MS instrument is developed that can separate proteins in a first dimension, digest them inside a pepsin-immobilized microreactor, separate peptides in a second dimension, and detect the peptides with MS. The development begins from the MS end by coupling capillary free zone electrophoresis (CZE) to a linear ion trap mass spectrometer with a sheath flow interface, and works its way forward to the protein separation.Two CE-MS interfaces are tested and a sheath flow configuration is chosen for further instrument development because it provides robust electrosprays and does not cause band broadening. The CZE separation is optimized using bulk solution digested cytochrome C. Peptide-capillary wall interactions are reduced by coating capillaries with poly(vinyl alcohol) and by using high ionic strength buffers. The information dependent acquisition (IDA) capability of the mass spectrometer is used to obtain peptide fragment mass spectra that are submitted to a protein database search engine to identify cytochrome C.Pepsin-immobilized monolithic capillary microreactors are prepared and their homogeneity and digestion efficiency are investigated in both off-line and on-line experiments with CZE-ESI-MS. On-line coupling is achieved with a Plexiglas-glass interface. The microreactors are rather heterogeneous, yet cytochrome C was still successfully digested within 2 min. Hydroquinone (and p-benzoquinone) is added to buffers to alleviate CE current instabilities due to the electrolysis of water.The instrument is modified to a 2D CE-UV-microreactor-CE-ESI-MS-MS system by adding a protein separation capillary in front of the peptide separation. The protein separation capillary end that is coupled to the peptide separation dimension has an ∼ 1 cm microreactor integrated in it. A cytochrome C and myoglobin mixture is separated and identified using this 2D system. Only myoglobin is detected in a 6 protein sample, possibly because the other proteins contain disulfide bonds and/or are pepsin-resistant.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Schoenherr, Regine M

Rights

dc:rights
Statement dc:rights
  • Copyright is held by the individual authors.
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Dc Identifier Other
b58871822
191680448
OAI identifier oai:identifier
oai:digital.lib.washington.edu:1773/11593

Chain of custody

source
Harvested from
University of Washington
Base URL
digital.lib.washington.edu/server/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Schoenherr, Regine M. CE-microreactor-CE-MS-MS for protein analysis. 2006. http://hdl.handle.net/1773/11593