Back to results

Virginia Tech

A wind tunnel facility for the evaluation of a land-based gas turbine diffuser-collector

Abstract

dc:description.abstract

A subsonic wind tunnel facility was built and tested as part of a base line test investigating flow within a diffuser-collector. Facility controls allowed the quarter scale model to match both Reynolds number and Mach number. Mass averaged conditions at the diffuser inlet during testing were determined as 1.939 ? 106 for Reynolds number based upon diffuser inlet hydraulic diameter, and 0.418 for Mach number. A flow conditioning section prior to test section contained several interchangeable sections. Flow conditioning components were used to create flow characteristic of that leaving the last stage of a land-based gas turbine. The diffuser-collector subsystem was evaluated through the use of wall static pressure measurements, a variety of probe traverse measurements, and Stereo-PIV. Flow within the collector and diffuser were determined to be heavily dependent upon the collector geometry. PIV measurements showed the development of two large counter rotating vortices within the collector. Each symmetric vortex grew and shifted according to the collector geometry while creating complex regions of flow. Pressure recovery within the diffuser was in range of 0.47 to 0.78, and would drop to 0.52 at the collector exit. The drop in pressure recovery was presumed to be a combination of inefficient diffusion in the collector and losses due to the vortices. The baseline test was found to be successful in terms of facility design, and determining the critical flow phenomena. Further testing and experimentation are necessary to evaluate specific details of the collector geometry's effect upon the pressure recovery and flow development.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Samal, Nihar Ranjan
Chairs dc:contributor.committeechair
  • Ng, Wing Fai
  • Lowe, K. Todd
  • Dancey, Clinton L.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Dc Identifier Other
etd-12202011-172031
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/76931

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Samal, Nihar Ranjan. A wind tunnel facility for the evaluation of a land-based gas turbine diffuser-collector. masters thesis, Virginia Tech, 2011. http://hdl.handle.net/10919/76931