{"id":{"repo_id":"vt","oai_identifier":"oai:vtechworks.lib.vt.edu:10919/76931"},"canonical_url":"https://search.dev.ndltd.org/etd/vt/oai:vtechworks.lib.vt.edu:10919/76931","repository":{"repo_id":"vt","name":"Virginia Tech","base_url":"https://vtechworks.lib.vt.edu/oai/request"},"display":{"title":"A wind tunnel facility for the evaluation of a land-based gas turbine diffuser-collector","abstract":"A subsonic wind tunnel facility was built and tested as part of a base line test investigating flow within a diffuser-collector. Facility controls allowed the quarter scale model to match both Reynolds number and Mach number. Mass averaged conditions at the diffuser inlet during testing were determined as 1.939 ? 106 for Reynolds number based upon diffuser inlet hydraulic diameter, and 0.418 for Mach number. A flow conditioning section prior to test section contained several interchangeable sections. Flow conditioning components were used to create flow characteristic of that leaving the last stage of a land-based gas turbine. The diffuser-collector subsystem was evaluated through the use of wall static pressure measurements, a variety of probe traverse measurements, and Stereo-PIV. Flow within the collector and diffuser were determined to be heavily dependent upon the collector geometry. PIV measurements showed the development of two large counter rotating vortices within the collector. Each symmetric vortex grew and shifted according to the collector geometry while creating complex regions of flow. Pressure recovery within the diffuser was in range of 0.47 to 0.78, and would drop to 0.52 at the collector exit. The drop in pressure recovery was presumed to be a combination of inefficient diffusion in the collector and losses due to the vortices. The baseline test was found to be successful in terms of facility design, and determining the critical flow phenomena. Further testing and experimentation are necessary to evaluate specific details of the collector geometry's effect upon the pressure recovery and flow development.","abstract_html":"A subsonic wind tunnel facility was built and tested as part of a base line test investigating flow within a diffuser-collector. Facility controls allowed the quarter scale model to match both Reynolds number and Mach number. Mass averaged conditions at the diffuser inlet during testing were determined as 1.939 ? 106 for Reynolds number based upon diffuser inlet hydraulic diameter, and 0.418 for Mach number. A flow conditioning section prior to test section contained several interchangeable sections. Flow conditioning components were used to create flow characteristic of that leaving the last stage of a land-based gas turbine. The diffuser-collector subsystem was evaluated through the use of wall static pressure measurements, a variety of probe traverse measurements, and Stereo-PIV. Flow within the collector and diffuser were determined to be heavily dependent upon the collector geometry. PIV measurements showed the development of two large counter rotating vortices within the collector. Each symmetric vortex grew and shifted according to the collector geometry while creating complex regions of flow. Pressure recovery within the diffuser was in range of 0.47 to 0.78, and would drop to 0.52 at the collector exit. The drop in pressure recovery was presumed to be a combination of inefficient diffusion in the collector and losses due to the vortices. The baseline test was found to be successful in terms of facility design, and determining the critical flow phenomena. Further testing and experimentation are necessary to evaluate specific details of the collector geometry&#x27;s effect upon the pressure recovery and flow development.","abstract_has_math":false,"creators":["Samal, Nihar Ranjan"],"institution":"Virginia Tech","degree_name":"Master of Science","degree_level":"masters","degree_discipline":"Mechanical Engineering","degree_department":"Mechanical Engineering","school":null,"contributors":[],"advisors":[],"committee_chairs":["Ng, Wing Fai","Lowe, K. Todd","Dancey, Clinton L."],"committee_members":[],"year":2011,"date_issued":"2011-12-07","date_published":"2011-12-07","updated_at":"2026-07-22T22:19:45Z","subjects":["Annular diffuser","Diffuser-Collector","Exhaust hood","Pressure recovery","Stereo-PIV"],"languages":["en_US"],"rights":["In Copyright"],"rights_urls":["http://rightsstatements.org/vocab/InC/1.0/"],"identifier_entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-12202011-172031"],"render_values":[{"text":"etd-12202011-172031","href":null,"code":true}]}]},"links":{"outbound_url":"http://hdl.handle.net/10919/76931","outbound_label":"Handle","outbound_source":"dc:identifier.uri"},"metadata_groups":[{"id":"people","label":"People","entries":[{"key":"dc:contributor.committeechair","label":"Committee Chair","values":["Ng, Wing Fai","Lowe, K. Todd","Dancey, Clinton L."]},{"key":"dc:contributor.department","label":"Department","values":["Mechanical Engineering"]},{"key":"dc:creator","label":"Author","values":["Samal, Nihar Ranjan"]}]},{"id":"academic_context","label":"Academic Context","entries":[{"key":"dc:date.accessioned","label":"Dc Date Accessioned","values":["2017-04-04T19:50:23Z"]},{"key":"dc:date.available","label":"Dc Date Available","values":["2017-04-04T19:50:23Z","2016-10-17"]},{"key":"dc:date.issued","label":"Date","values":["2011-12-07"]},{"key":"dc:publisher","label":"Institution","values":["Virginia Tech"]},{"key":"dc:type","label":"Dc Type","values":["Thesis"]},{"key":"dc:type.dcmitype","label":"Dc Type Dcmitype","values":["Text"]},{"key":"thesis:degree_discipline","label":"Discipline","values":["Mechanical Engineering"]},{"key":"thesis:degree_level","label":"Degree Level","values":["masters"]},{"key":"thesis:degree_name","label":"Degree Name","values":["Master of Science"]},{"key":"thesis:institution_name","label":"Thesis Institution Name","values":["Virginia Polytechnic Institute and State University"]}]},{"id":"subjects_keywords","label":"Subjects and Keywords","entries":[{"key":"dc:subject","label":"Dc Subject","values":["Annular diffuser","Diffuser-Collector","Exhaust hood","Pressure recovery","Stereo-PIV"]}]},{"id":"language_rights","label":"Language and Rights","entries":[{"key":"dc:language.iso","label":"Language (ISO)","values":["en_US"]},{"key":"dc:rights","label":"Dc Rights","values":["In Copyright"]},{"key":"dc:rights.uri","label":"Rights URI","values":["http://rightsstatements.org/vocab/InC/1.0/"]}]},{"id":"identifiers","label":"Identifiers","entries":[{"key":"dc:identifier.other","label":"Dc Identifier Other","values":["etd-12202011-172031"]},{"key":"dc:identifier.uri","label":"Identifier URI","values":["http://hdl.handle.net/10919/76931"]}]},{"id":"additional","label":"Additional Metadata","entries":[{"key":"dc:description.abstract","label":"Abstract","values":["A subsonic wind tunnel facility was built and tested as part of a base line test investigating flow within a diffuser-collector. Facility controls allowed the quarter scale model to match both Reynolds number and Mach number. Mass averaged conditions at the diffuser inlet during testing were determined as 1.939 ? 106 for Reynolds number based upon diffuser inlet hydraulic diameter, and 0.418 for Mach number. A flow conditioning section prior to test section contained several interchangeable sections. Flow conditioning components were used to create flow characteristic of that leaving the last stage of a land-based gas turbine. The diffuser-collector subsystem was evaluated through the use of wall static pressure measurements, a variety of probe traverse measurements, and Stereo-PIV. Flow within the collector and diffuser were determined to be heavily dependent upon the collector geometry. PIV measurements showed the development of two large counter rotating vortices within the collector. Each symmetric vortex grew and shifted according to the collector geometry while creating complex regions of flow. Pressure recovery within the diffuser was in range of 0.47 to 0.78, and would drop to 0.52 at the collector exit. The drop in pressure recovery was presumed to be a combination of inefficient diffusion in the collector and losses due to the vortices. The baseline test was found to be successful in terms of facility design, and determining the critical flow phenomena. Further testing and experimentation are necessary to evaluate specific details of the collector geometry's effect upon the pressure recovery and flow development."]},{"key":"dc:description.degree","label":"Dc Description Degree","values":["Master of Science"]},{"key":"dc:title","label":"Title","values":["A wind tunnel facility for the evaluation of a land-based gas turbine diffuser-collector"]}]}],"canonical_facts":{"dc:contributor.committeechair":["Ng, Wing Fai","Lowe, K. Todd","Dancey, Clinton L."],"dc:contributor.department":["Mechanical Engineering"],"dc:creator":["Samal, Nihar Ranjan"],"dc:date.accessioned":["2017-04-04T19:50:23Z"],"dc:date.available":["2017-04-04T19:50:23Z","2016-10-17"],"dc:date.issued":["2011-12-07"],"dc:description.abstract":["A subsonic wind tunnel facility was built and tested as part of a base line test investigating flow within a diffuser-collector. Facility controls allowed the quarter scale model to match both Reynolds number and Mach number. Mass averaged conditions at the diffuser inlet during testing were determined as 1.939 ? 106 for Reynolds number based upon diffuser inlet hydraulic diameter, and 0.418 for Mach number. A flow conditioning section prior to test section contained several interchangeable sections. Flow conditioning components were used to create flow characteristic of that leaving the last stage of a land-based gas turbine. The diffuser-collector subsystem was evaluated through the use of wall static pressure measurements, a variety of probe traverse measurements, and Stereo-PIV. Flow within the collector and diffuser were determined to be heavily dependent upon the collector geometry. PIV measurements showed the development of two large counter rotating vortices within the collector. Each symmetric vortex grew and shifted according to the collector geometry while creating complex regions of flow. Pressure recovery within the diffuser was in range of 0.47 to 0.78, and would drop to 0.52 at the collector exit. The drop in pressure recovery was presumed to be a combination of inefficient diffusion in the collector and losses due to the vortices. The baseline test was found to be successful in terms of facility design, and determining the critical flow phenomena. Further testing and experimentation are necessary to evaluate specific details of the collector geometry's effect upon the pressure recovery and flow development."],"dc:description.degree":["Master of Science"],"dc:identifier.other":["etd-12202011-172031"],"dc:identifier.uri":["http://hdl.handle.net/10919/76931"],"dc:language.iso":["en_US"],"dc:publisher":["Virginia Tech"],"dc:rights":["In Copyright"],"dc:rights.uri":["http://rightsstatements.org/vocab/InC/1.0/"],"dc:subject":["Annular diffuser","Diffuser-Collector","Exhaust hood","Pressure recovery","Stereo-PIV"],"dc:title":["A wind tunnel facility for the evaluation of a land-based gas turbine diffuser-collector"],"dc:type":["Thesis"],"dc:type.dcmitype":["Text"],"thesis:degree_discipline":["Mechanical Engineering"],"thesis:degree_level":["masters"],"thesis:degree_name":["Master of Science"],"thesis:institution_name":["Virginia Polytechnic Institute and State University"]},"updated_at":"2026-07-22T22:19:45Z"}