Back to results

Virginia Tech

Development of a Hollow-Core Fiberoptic Microneedle Device for the Treatment of Invasive Bladder Cancer

Abstract

dc:description.abstract

The hydraulic resistance characterization manuscript chronicles the early development of the hollow-core fiberoptic microneedle device (FMD). The study determined that for straight tubing with an inner bore of 150 ?m and a length greater than 50 mm long, Poiseuille's Law was shown to be accurate within 12% of experimental data for the pressure range of 69-517 kPa. Comparison between different needle design geometries indicated that tip diameters <55 ?m cause a significant increase in hydraulic resistance. Tubing length should be kept to a minimum and tip diameter should be kept above this threshold to reduce overall hydraulic resistance. The bladder treatment study describes the fabrication and testing of the FMD for treatment of invasive urothelial cell carcinomas (UCCs). Experiments investigating the fluid dispersal of single-walled carbon nanohorns (SWNHs) in the wall of inflated, healthy ex vivo bladders demonstrated that perfusion of 2 cm° on the bladder wall's surface can be achieved with a 5 minute infusion at 50 ?L/min. Irradiation of the SWNH perfused bladder wall tissue with a free space, 1064 nm laser at an irradiance of 0.95 W/cm° for 40 seconds yielded a 480% temperature increase relative to similar irradiation of a non-infused control. Co-delivery experiments demonstrated both SWNH and light delivery though a single hollow-core fiber to heat the bladder wall 33 °C with an irradiance of 400 W/cm°, demonstrating that the FMD can be used to achieve hyperthermia-based therapeutic effects via interstitial irradiation.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Biomedical Engineering
Department dc:contributor.department
Biomedical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Hood, Robert L.
Chair dc:contributor.committeechair
  • Rylander, Christopher G.
Committee members dc:contributor.committeemember
  • Robertson, John L.
  • Rylander, M. Nichole
  • Grant, David C.

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en_US

Identifiers

dc:identifier.*
Dc Identifier Other
etd-08192011-131101
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/76846

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation