Abstract
dc:description.abstractAdvancements in design technology and construction materials have allowed composite floor systems to become longer and shallower. As a result, serviceability considerations rather than strength considerations have started to control designs. Partial continuity in composite floor systems has been suggested as a means by which the serviceability aspects could be improved. A new beam-to-girder connection referred to as a composite semi-rigid beam-to-girder connection is investigated as a possible method to provide partial continuity in floor systems. Four of these connections are evaluated experimentally and analytically to determine their behavior and the feasibility of their use in typical composite floor systems. The results indicate that these connections would improve serviceability aspects of the floor system and would improve the general efficiency of the floor design.
Degree
thesis:*- Name thesis:degree_name
- Master of Science
- Level thesis:degree_level
- masters
- Discipline thesis:degree_discipline
- Civil Engineering
- Department dc:contributor.department
- Civil Engineering
- Grantor dc:publisher
- Virginia Tech
- Year dc:date.issued
- 1994
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Rex, Clinton O.
Rights
dc:rights- Statement dc:rights
-
- In Copyright
- Licence dc:rights.uri
- Language dc:language.iso
- en
Identifiers
dc:identifier.*- Dc Identifier Other
- etd-07102009-040338
- OAI identifier oai:identifier
- oai:vtechworks.lib.vt.edu:10919/43620