  1. The Force Floor: Design and Development of a Low-Cost 3D Force Sensing Area Which Utilises Machine Learning to Estimate 3D GRF and CoP from Single-Axis Loadcells

    … in its behaviour. This research investigates the design and small-scale manufacture (to 20 units) of a low-cost force plate design that utilises a machine learning model to overcome these limitations and estimate 3D GRF and centre of pressure from a series of single-axis loadcells. A literature …

    cape-town Repository record for The Force Floor: Design and Development of a Low-Cost 3D Force Sensing Area Which Utilises Machine Learning to Estimate 3D GRF and CoP from Single-Axis Loadcells (opens in a new tab)

  2. Behavior of composite semi-rigid beam-to-girder connections

    Advancements in design technology and construction materials have allowed composite floor systems to become longer and shallower. As a result, serviceability considerations rather than strength considerations have started to control designs. Partial continuity in composite floor systems has been …

    vt Repository record for Behavior of composite semi-rigid beam-to-girder connections (opens in a new tab)

  3. Sketches Count: The Mies Van Der Rohe’s Dirksen Courthouse Archive Redrawn

    … conventions underlying contemporary courthouse design. Archived in the Mies van der Rohe Archive at the Museum of Modern Art New York, a significant resource associated with the design of the courthouse is the extensive documentation of the design process at the office of Mies. This body of work …

    gatech Repository record for Sketches Count: The Mies Van Der Rohe’s Dirksen Courthouse Archive Redrawn (opens in a new tab)

  4. A study of the design and thermal performance of two-storey earth sheltered houses for the UK climate

    … residential development in South Wales, UK. When designed as Exposed South Wall type earth sheltered houses, which incorporate a number of passive solar design principles, each house provides a ratio of 0.508 for the internal floor area to the overall plot area, which is more efficient than 0.319 …

    southwales Repository record for A study of the design and thermal performance of two-storey earth sheltered houses for the UK climate (opens in a new tab)

  5. Behavior and modeling of partially restrained beam-girder connections

    Beams in a typical steel framed floor design are assumed to have pinned supports for purposes of design. In reality, the connections between the beams and girders in a steel framed floor system are not pinned. The design bending moments and deflections of the attached beam could be reduced if the …

    vt Repository record for Behavior and modeling of partially restrained beam-girder connections (opens in a new tab)

  6. Experimental and Theoretical Investigations of a New Flat Slab System Incorporating GFRP Stay-In-Place Structural Forms and Embedded I-Beams

    A novel steel-free concrete flat-slab design for floors is introduced. It includes embedded glass fiber-reinforced polymer (GFRP) I-sections as primary and secondary beams, with columns supporting the primary beams. GFRP stay-in-place (SIP) structural forms span the spacing between, and are bonded …

    queens Repository record for Experimental and Theoretical Investigations of a New Flat Slab System Incorporating GFRP Stay-In-Place Structural Forms and Embedded I-Beams (opens in a new tab)

  7. Strength Calculation Model for Standoff Screws in Composite Joists

    … compatible with the Load Factor Resistance Design (LRFD) procedure that would allow the use of this shear connector in design of composite floor systems. The study considers results from push-out tests using this type of screw reported by Hankins et al. (1994), Alander et al. (1998), Webler …

    vt Repository record for Strength Calculation Model for Standoff Screws in Composite Joists (opens in a new tab)

  8. Floor Vibrations: Girder Effective Moment of Inertia and Cost Study

    … analysis comparing composite and non-composite floor systems that meet vibrations design standards, were conducted. The first study was undertaken because over-prediction of girder effective moment of inertia was the suspected cause of several recent vibration problems in floors supported by …

    vt Repository record for Floor Vibrations: Girder Effective Moment of Inertia and Cost Study (opens in a new tab)