Back to results

Virginia Tech

Supercritical fluid extraction as a sample preparation technique for the isolation of polar pharmaceutical compounds

Abstract

dc:description.abstract

The low polarity of the supercritical fluid extraction (SFE) solvent, CO₂, causes problems when applying this technique to polar compounds. The objective of this research was to expand the applicability of SFE to include polar compounds. The first phase of this research investigated "inverse SFE", which is the selective extraction of the matrix while leaving behind the target analytes, as a means of isolating four polar polymyxin sulfate compounds from several challenging matrices due to the liquid-like consistency and the low concentrations (ppm) of the target analytes. Higher recoveries (>100%) were achieved with low RSD's (5.0 and 1.9% for two separate matrices), compared to the conventional method of isolation, solid phase extraction. The second portion of this research investigated the effect of high levels of polar modifier on trapping efficiency. The mode of modifier introduction was found to have a considerable effect on trapping efficiency, as in-line modifier addition rather than matrix spiking was determined to be best when introducing high levels of liquid modifier. Also, three separate mechanisms, aerosol formation, blow-by, and modifier elution, were identified which caused analyte loss at the solid phase trap, and the extraction and trapping conditions for which each mechanism was most favorable were identified. The next phase of this research developed two separate SFE methods which were used to isolate two pharmaceuticals from leaves. Each SFE method reduced the time, sample handling, costs, and liquid solvents needed as compared to the conventional liquid extraction technique. While achieving comparable recoveries, reproducibilities were much improved for the two SFE methods with RSD's of 3.8 and 5.2%, respectively, while the liquid extraction technique yielded RSD's of 14%. The last phase of this research investigated several strategies for improving selectivity in SFE. Three separate strategies for improving selectivity were studied: 1) alternative fluids (pure and modified fluoroform and tetrafluoroethane), 2) pre-extraction, and 3) selective rinsing of the solid phase trap. Advantages were realized with each technique, and it was concluded that they be used in conjunction with one another in order to maximize selectivity.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Chemistry
Department dc:contributor.department
Chemistry
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1996

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Moore, William N.
Chair dc:contributor.committeechair
  • Taylor, Larry T.
Committee members dc:contributor.committeemember
  • Tissue, Brian M.
  • McNair, Harold M.
  • Brewer, Karen J.
  • Bell, Harold M.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
etd-10052007-143203
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/39639

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Moore, William N.. Supercritical fluid extraction as a sample preparation technique for the isolation of polar pharmaceutical compounds. doctoral thesis, Virginia Tech, 1996. http://hdl.handle.net/10919/39639