Back to results

Virginia Tech

Physiological and Metabolic Responses to Constant-Load Exercise on an Inclined Stepper and Treadmill

Abstract

dc:description.abstract

This study evaluated oxygen uptake (VO2), heart rate (HR), and lactate [HLa] responses between the treadmill (TM) and the CardiosquatTM 1650 LETM inclined stepper by StairMasterTM (SM) during constant-load exercise. The slow component of VO2 (SC) was a central variable assessed during exercise. Twenty-two healthy college-aged (18-30) subjects completed an incremental TM and SM exercise test to establish a workload equivalent to 70% VO2peak. Following each incremental test, a 20-minute constant-load exercise bout was performed . Incremental and instant-load exercise bouts were separated by at least 48 hours. The order of the tests were randomized. VO2, HR, and [HLa] were evaluated at 5, 10, 15, and 20-minutes of exercise. Expired gases were analyzed using a Med Graphics CPX/D metabolic cart. Blood samples were analyzed immediately for lactate concentration with an automated lactate analyzer (Yellow Springs Instrument Model 1500 Sport ). A two-way ANOVA with repeated measures was performed on the rate of change between the treadmill and stepper for VO2, HR, and [HLa]. No significant differences were found for any of the response variables (P>0.05). These results suggest at that the same relative workload, the SM does not elicit a more pronounced SC than the TM. Based on these findings, the SM appears to be an appropriate modality of exercise for various clinical populations.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Human Nutrition, Foods, and Exercise
Department dc:contributor.department
Human Nutrition, Foods, and Exercise
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
1997

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rieger, Brian W.
Chair dc:contributor.committeechair
  • Davis, Shala E.
Committee members dc:contributor.committeemember
  • Redican, Kerry J.
  • Sebolt, Don R.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-3621142439741131
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/36647

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Rieger, Brian W.. Physiological and Metabolic Responses to Constant-Load Exercise on an Inclined Stepper and Treadmill. masters thesis, Virginia Tech, 1997. http://hdl.handle.net/10919/36647