Back to results

Virginia Tech

Treatment of Ischemic Equine Jejunum with Topical and Intraluminal Carolina Rinse

Abstract

dc:description.abstract

Carolina Rinse (CRS) has been shown to be effective in decreasing vascular permeability and neutrophil infiltration in reperfused equine small intestine. The objective of this study was to show that CRS applied topically and intraluminally could prevent immediate reperfusion injury after low flow ischemia or distention in the equine jejunum. Materials & Methods: Two groups of 5 horses were used to evaluate CRS treatment after low-flow ischemia (Group 1) and intraluminal distention (Group 2) of distal jejunum. Mesenteric blood flow, osmotic reflection coefficient (ORC), wet weight to dry weight ratios (WW/DW), and neutrophil accumulation in the serosa were measured. ORC is defined as the lymph protein concentration to plasma protein concentration ratio subtracted from one (1- Cl / Cp) at maximal lymph flow. The ORC from baseline values and at 60 minutes after initiating reperfusion was compared between Groups 1 and 2. Pair wise comparisons were made for mesenteric blood flow, tissue volume, neutrophil number, and WW/DW proximal control and CRS treated jejunal segments were made using a Mann Whitney U test (P< 0.05). Results: The mean ORC of bowel treated topically and intraluminally with CRS was similar to that recorded in normal bowel or ischemic intestine treated with CRS by arterial perfusion. The ORC after distention and decompression increased and was similar to that reported in untreated intestine. The WW/DW after both ischemia and distention increased compared to the proximal control segments. There was no difference in neutrophil number in either ischemic or distended intestine compared to the proximal control segments. Discussion: Carolina CRS was effective in preventing alterations in microvascular permeability during reperfusion afterischemia but not distention. Neutrophil migration curtailed in both groups suggesting that combined topical and intraluminal application of CRS to ischemic intestine may reduce the acute inflammatory responses during reperfusion thereby decreasing complications after ischemia or distention.

Degree

thesis:*
Name thesis:degree_name
Master of Science
Level thesis:degree_level
masters
Discipline thesis:degree_discipline
Veterinary Medical Sciences
Department dc:contributor.department
Veterinary Medical Sciences
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2001

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Young, Byron Leslie
Chair dc:contributor.committeechair
  • White, Nathaniel A. II
Committee members dc:contributor.committeemember
  • Crisman, Mark V.
  • Donaldson, Lydia L.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-07152001-150510
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/34012

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Young, Byron Leslie. Treatment of Ischemic Equine Jejunum with Topical and Intraluminal Carolina Rinse. masters thesis, Virginia Tech, 2001. http://hdl.handle.net/10919/34012