Back to results

Virginia Tech

Reliability and Validity of Mechanical Response Tissue Analysis in Composite and Human Tibiae

Abstract

dc:description.abstract

The purpose of this study was to assess the validity, as well as to test novel approaches to improving the reliability, of mechanical response tissue analysis (MRTA). Twenty composite tibiae underwent MRTA testing on three separate days to determine intra- and inter-day reliability of bending stiffness. The bones were then subjected to three-point bending tests to directly determine elastic modulus. Within- and between-day reliability of tibial bending stiffness with MRTA was moderate (CV = 24%) and poor (CV = 74%), respectively. No relationship was observed between the two testing methods due to the wide variation in tibial bending stiffness values with MRTA. The second part of the study sought to determine within- and between-day reliability of MRTA in young women with the current testing protocol and compare the results with those from newly-designed protocols. Twelve women (23 ± 2 yr, 162 ± 7 cm, 57 ± 7kg, 19 ± 4 % fat) were tested for tibial bending stiffness with MRTA over 5 days. The current protocol was compared to protocols where day-to-day subject positioning was quantified, subjects were tested in a supine position, and various bending stiffness prediction models were used. Within- (CV = 20%) and between-day (CV = 19%) reliability of tibial bending stiffness with MRTA was moderate using the original methodology. Modifications to this protocol either resulted in similar or worse reliability.

Degree

thesis:*
Name thesis:degree_name
Ph. D.
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Human Nutrition, Foods, and Exercise
Department dc:contributor.department
Human Nutrition, Foods, and Exercise
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2003

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Miller, Larry Edwin
Chair dc:contributor.committeechair
  • Herbert, William G.
Committee members dc:contributor.committeemember
  • Cross, Lawrence H.
  • Nickols-Richardson, Sharon M.
  • Gwazdauskas, Francis C.
  • Ramp, Warren K.

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • In Copyright

Identifiers

dc:identifier.*
Dc Identifier Other
etd-07142003-172355
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/28293

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Miller, Larry Edwin. Reliability and Validity of Mechanical Response Tissue Analysis in Composite and Human Tibiae. doctoral thesis, Virginia Tech, 2003. http://hdl.handle.net/10919/28293