Back to results

Virginia Tech

Enhanced Portability and Anti-Frosting Functionality of Cryostats for Synchrotron-Based X-ray Imaging

Abstract

dc:description.abstract

The intensity of light produced from synchrotrons enables X-ray imaging down to the micron and submicron scale. This high degree of resolution is necessary to study metals in hydrated biological samples, where trace (metal) elements are found in the lowest concentration. Water within these aqueous samples will undergo radiolysis and produce various reactive oxygen species, which degrades the quality of information gathered from the sample during X-ray imaging. Studies have shown that the best way to counter the effects of radiolysis and preserve samples in their metabolic state during X-ray imaging is to keep them cryogenically frozen. We have developed affordable cryostats and novel protocol to not only improve cryo-imaging at current third-generation synchrotrons, but also enable cryo-imaging at existing synchrotrons that have limited accessibility. This dissertation will provide a detailed description of the tasks that were accomplished to contribute to the development cryo-imaging. The first task was the fabrication of a portable cryostage. The cryostage's discreet profile and unique design successfully enabled it to be effortlessly adapted into three beamlines across two different DOE facilities and facilitate multiple imaging modalities, i.e., correlative imaging. With the next task, we explored adding an ice frame about the stage to help reduce the accumulation of frost on the surface of a frozen sample that was explored. The addition of the ice frame significantly improved the imaging of frozen samples, nearly doubling the overall image clarity in comparison to when it was absent. The final task saw the application of a cryostream, in place of a cryostage, to provide a cooled convective flux across the sample for 2D and 3D visualization for cryo X-ray imaging.

Degree

thesis:*
Name thesis:degree_name
Doctor of Philosophy
Level thesis:degree_level
doctoral
Discipline thesis:degree_discipline
Mechanical Engineering
Department dc:contributor.department
Mechanical Engineering
Grantor dc:publisher
Virginia Tech
Year dc:date.issued
2022

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Lowery, Adam Wallace
Chair dc:contributor.committeechair
  • Boreyko, Jonathan B.
Committee members dc:contributor.committeemember
  • Miller, Lisa M.
  • Ben-Tzvi, Pinhas
  • Paul, Mark R.
  • Huxtable, Scott T.

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • In Copyright
Language dc:language.iso
en

Identifiers

dc:identifier.*
Dc Identifier Other
vt_gsexam:35312
OAI identifier oai:identifier
oai:vtechworks.lib.vt.edu:10919/111590

Chain of custody

source
Harvested from
Virginia Tech
Base URL
vtechworks.lib.vt.edu/oai/request
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Lowery, Adam Wallace. Enhanced Portability and Anti-Frosting Functionality of Cryostats for Synchrotron-Based X-ray Imaging. doctoral thesis, Virginia Tech, 2022. http://hdl.handle.net/10919/111590