Back to results

University of Texas Health Science Center at Houston

Characterization of Oslds For Use In Small Field Photon Beam Dosimetry

Abstract

dc:description.abstract

<p>The goal of this study was to redesign a Radiological Physics Center (RPC) mailable remote audit tool used for stereotactic radiosurgery (SRS) single beam dosimetry. A prototype phantom was designed and built housing nanoDot (Landauer Inc., Glenwood, IL) Al<sub>2</sub>O<sub>3</sub>:C optically stimulated luminescence dosimeters (OSLDs) whose visible active luminescent area has been masked. The phantom has two measurement points with two OSLDs at each location and a film insert for localization purposes only. The masked OSLDs were characterized accounting for various correction factors associated with OSLD dose calculations. The uncertainties for each correction factor were also investigated. It was determined that the linearity, depletion, fading, and energy correction factors were identical to the RPC commissioning data for non-masked OSLDs. The element correction factor (ECF) for masked OSLDs must be determined separately. Two new correction factors were introduced to the OSL dose calculation formula, scatter and field size dependence factor. The field size dependence factor was proven to be unity. The minimum field size the masked OSLD system can accommodate as an audit tool was determined to be 10 mm diameter field for circular cones or 1 x 1 cm<sup>2</sup> field sizes. The overall system uncertainty was 3.72% (95% C.I.) for irradiations performed using a 1 x 1 cm<sup>2</sup> field size. The uncertainty was suitable in advocating a ±5% acceptance criterion for RPC remote audits. Feasibility studies were performed at various locations on multiple SRS treatment configurations. CyberKnife, linac based cones, and MLC trial audits produced an average RPC OSLD measured to institution reported dose ratio of 0.982 with a standard deviation of 0.036.</p>

Degree

thesis:*
Name thesis:degree_name
Masters of Science (MS)
Level thesis:degree_level
Thesis (MS)
Year dc:date.available
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Pham, Christopher
Contributors dc:contributor
  • David Followill, Ph.D.
  • Stephen Kry, Ph.D.
  • Paola Alvarez, M.S.

Subjects

dc:subject × 6

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:digitalcommons.library.tmc.edu:utgsbs_dissertations-1439

Chain of custody

source
Harvested from
University of Texas Health Science Center at Houston
Base URL
digitalcommons.library.tmc.edu/do/oai/
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
citation

Pham, Christopher. Characterization of Oslds For Use In Small Field Photon Beam Dosimetry. Thesis (MS) thesis, 2013. https://digitalcommons.library.tmc.edu/utgsbs_dissertations/401