  1. Understanding The Influence of Photon Energy On 6Mv Non Reference Dosimetry and Ct Dosimetry Using Tld and Osld

    … and optically stimulated luminescent dosimeters (OSLD).</p> <p>There were two main objectives to this work. The first objective was to evaluate the energy dependence of TLD and OSLD for non-reference measurement conditions in a radiotherapy environment. The second objective was to fully …

    uthsc Repository record for Understanding The Influence of Photon Energy On 6Mv Non Reference Dosimetry and Ct Dosimetry Using Tld and Osld (opens in a new tab)

  2. Development and Implementation of The Use of Optically Stimulated Luminescent Detectors In The Radiological Physics Center Anthropomorphic Quality Assurance Phantoms

    … to optically stimulated luminescent dosimeters (OSLDs), but a problem lies in the angular dependence exhibited by the OSLD. The purpose of this study was to characterize the angular dependence of OSLD and establish a correction factor if necessary, to provide accurate dosimetric measurements as a …

    uthsc Repository record for Development and Implementation of The Use of Optically Stimulated Luminescent Detectors In The Radiological Physics Center Anthropomorphic Quality Assurance Phantoms (opens in a new tab)

  3. Characterization of Oslds For Use In Small Field Photon Beam Dosimetry

    … optically stimulated luminescence dosimeters (OSLDs) whose visible active luminescent area has been masked. The phantom has two measurement points with two OSLDs at each location and a film insert for localization purposes only. The masked OSLDs were characterized accounting for various …

    uthsc Repository record for Characterization of Oslds For Use In Small Field Photon Beam Dosimetry (opens in a new tab)

  4. Development of A Remote Dosimetric Audit Framework For Carbon Therapy

    … and optically-stimulated luminescent dosimeters (OSLD) and GafChromic film.</p> <p>The aim of this work will be to characterize dosimeters and materials for use in carbon radiotherapy and combine these tools to create an end-to-end anthropomorphic phantom audit. The absorbed dose corrections …

    uthsc Repository record for Development of A Remote Dosimetric Audit Framework For Carbon Therapy (opens in a new tab)

  5. Measuring terrestrial wildlife external radiation exposure under field conditions

    … to identify four passive dosimeters (i.e. TLD, OSLD, RPLD and DIS), which should be suitable for reindeer. To protect these dosimeters during use, they were housed in an aluminium box that could be attached to a collar around the reindeer’s neck. The performance of dosimeters within the box was …

    salford Repository record for Measuring terrestrial wildlife external radiation exposure under field conditions (opens in a new tab)

  6. Extending The Lifetime of Optically Stimulated Dosimeters For Use In Output Checks At Iroc- Houston

    … Optically Stimulated Luminescent Dosimeters (OSLDs) are a prominent form of in-vivo dosimeter used both in clinics as well as for the audits of radiological<br />equipment at the Imaging and Radiation Oncology Core (IROC)-Houston. These<br />dosimeters have a recommended dose limit of 10 Gy …

    uthsc Repository record for Extending The Lifetime of Optically Stimulated Dosimeters For Use In Output Checks At Iroc- Houston (opens in a new tab)

  7. Development and Implementation of A Remote Audit to ol For High Dose Rate (Hdr) 192Ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry

    <p>This work aimed to create a mailable and OSLD-based phantom with accuracy suitable for RPC audits of HDR brachytherapy sources at institutions participating in NCI-funded cooperative clinical trials. An 8 × 8 × 10 cm<sup>3</sup> prototype with two slots capable of holding nanoDot …

    uthsc Repository record for Development and Implementation of A Remote Audit to ol For High Dose Rate (Hdr) 192Ir Brachytherapy Using Optically Stimulated Luminescence Dosimetry (opens in a new tab)

  8. Characterization of Optically Stimulated Luminescent Detectors In Photon & Proton Beams For Use In Anthropomorphic Phantoms

    … of optically stimulated luminescent detectors (OSLDs) in protons, allowing comparison to thermoluminescent detectors, and to be implemented into the Radiological Physics Center’s (RPC) remote audit quality assurance program for protons, and for remote anthropomorphic phantom irradiations. The …