Back to results

University of Illinois at Urbana-Champaign

Improvements to power system dynamic load model parameter estimation

Abstract

dc:description

Transient stability analysis is becoming increasingly important for power systems engineers and researchers. Accurate dynamic models are required, but aggregate load models are an area of weakness. Measurement-based system identification methods based on least-squares minimization have difficulty uniquely identifying the model parameters because the models exhibit parameter insensitivity and interdependency: vastly different model parameters can produce the same output waveform for a given disturbance. One could argue that the parameters of a model are unimportant, as long as the simulation output waveforms are correct. While this is true for the training set — the disturbance(s) we used to determine the parameters — we show that, when measurement noise exists, the model fails when we try to use it to predict the result of other disturbances. We present three methods for reducing the effect of parameter unidentifiability. First, we try increasing the size of the training data to include multiple disturbances, but this does not have a significant impact. Second, we present an algorithm based on a maximum a-posteriori (MAP) estimator, which can take advantage of prior knowledge of the parameters of the grid. The MAP estimator is both more accurate and more robust than least squares. Third, we make use of complex power measurements in addition to voltage. Complex power was found to be much more robust to noise, but many more monitoring devices would need to be deployed to provide the necessary measurements. We also consider the practical computational aspects of large-scale parameter estimation. We propose a geographical region of influence method to define zones where lower resolution models could be substituted to reduce the computational burden. We then investigate alternative metrics for defining the difference between two time series, because the Euclidean distance was shown to be inadequate.

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Electrical & Computer Engr
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Guo, Siming
Contributors dc:contributor
  • Overbye, Thomas
  • Chen, Deming
  • Sauer, Peter
  • Zhu, Hao

Subjects

dc:subject × 12

Rights

dc:rights
Statement dc:rights
  • Copyright 2017 Siming Guo
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/97343
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/97343

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Guo, Siming. Improvements to power system dynamic load model parameter estimation. Dissertation thesis, University of Illinois at Urbana-Champaign, 2017. http://hdl.handle.net/2142/97343