Back to results

University of Illinois at Urbana-Champaign

Automated isotope identification algorithms for low-resolution gamma spectrometers

Abstract

dc:description

Handheld radio-isotope identifiers (RIIDs) are widely deployed for nuclear security applications, but these detectors generally have poor isotope identification performance. Most of these deployed detectors use low-resolution NaI scintillators due to their low cost and good efficiency. Alternative detection hardware could be used to improve performance, but better detectors are generally cost-prohibitive for wide deployment in this mission space. However, a trained spectroscopist can use these low-resolution detectors to make much more accurate identifications than the RIIDs produce. For this reason, it has been suggested that these RIIDs could be significantly improved by changing the onboard identification algorithms. To this end, a peak-based Bayesian classifier has been developed to perform automated isotope identification. This algorithm was constructed to mimic the manual identification that a spectroscopist would perform. This approach can handle challenges such as detector calibration drift and unknown shielding scenarios, is capable of identifying mixed radiation sources, and is computationally inexpensive enough to be feasible for deployment on handheld RIID systems. A method for easily generating isotope libraries that are coupled to the detector and to the feature extraction algorithm is presented as well. This method is demonstrated on a broad variety of gamma-ray spectra, ranging from small calibration sources ($<$ 1 μCi) to Category I quantities of special nuclear material. This algorithm is also benchmarked against the ANSI N42.34-2006 Standard for Handheld Identifiers as a part of the Department of Homeland Security Algorithm Improvement Program.

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Nuclear, Plasma, Radiolgc Engr
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2017

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Stinnett, Jacob Benjamin
Contributors dc:contributor
  • Sullivan, Clair J.
  • Stubbins, James F.
  • Ruzic, David N.
  • Varshney, Lav R.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Copyright 2016 Jacob Benjamin Stinnett
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/95304
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/95304

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Stinnett, Jacob Benjamin. Automated isotope identification algorithms for low-resolution gamma spectrometers. Dissertation thesis, University of Illinois at Urbana-Champaign, 2017. http://hdl.handle.net/2142/95304