Back to results

University of Illinois at Urbana-Champaign

Calibration of an accelerometer to measure physical activity in preschool children: A feasibility study

Abstract

dc:description

Physical activity measurements are essential for the evaluation and prevention of childhood obesity. Although physical activity (PA) data are currently collected with accelerometry, using the existing accelerometers had limitation with cost efficiency issues. The Best Fit Friend (BFF), a new accelerometer PA monitor system, was develop to solve the cost issue; however, validity of BFF to measure the PA in preschool children is still not clear. The primary purpose of this thesis was to examine the feasibility of BFF accelerometer for measure 3 to 5 year-olds preschoolers’ PA measurement. Based on the parental response and participant’s feedback, research and device feasibility were estimated. The second purpose was to validate the BFF accelerometer though a comparison with ActiGraph. Pearson correlation showed a moderate-high and/or high correlation between BFF accelerometer and ActiGraph. The third purpose was to clarify the difference of attachment placement: wrist and waist. Wilcoxon signed ranks test was to examine the statistical difference between dominant hand and non-dominant hand (Z = 4.99, p < .000, d = -.481), whereas there was not statistical differ with left wrist and waist, back and waist (Z = -1.39, p < .165, d = .130; Z = -.529, p < .597, d = -.050). The fourth purpose was to calibrate the BFF accelerometer to establish cut-off points. ROC curve analysis was performed. The last purpose was to decide the best placement of BFF accelerometer for children’s PA measurement. Based on comparison between AUC and cut-off, waist and back placements was the best BFF location, and right wrist, waist, and back conduct the best cut-off points. Overall, the BFF is a valid device to measure PA in preschool children ranged from 3 to 5 years old.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Kinesiology
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Shin, Jong Cheol
Contributors dc:contributor
  • Zhu, Weimo
  • McBride, Brent A.

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Copyright 2015 JongCheol Shin
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/88218
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/88218

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Shin, Jong Cheol. Calibration of an accelerometer to measure physical activity in preschool children: A feasibility study. Thesis thesis, University of Illinois at Urbana-Champaign, 2015. http://hdl.handle.net/2142/88218