University of Illinois at Urbana-Champaign
Bolted Flange Alternatives for Moment -Resisting Connections
Abstract
dc:descriptionThese alternative connections eliminated the backing bar, used high quality shop weld, and reduced the high stress and strain demand on the weld. Therefore, the failure of the bottom flange weld did not occur. However, for connections using the bottom girder flange component only, the inelastic mode of failure occurred at the top girder flange weld. Using the reduced flange plate at both the top girder flange and the bottom girder flange was the most effective method to develop large inelastic rotations of the joint with stable hysteretic behavior.
Degree
thesis:*- Name thesis:degree_name
- Ph.D.
- Level thesis:degree_level
- Dissertation
- Discipline thesis:degree_discipline
- Civil Engineering
- Grantor
- University of Illinois at Urbana-Champaign
- Year dc:date
- 2015
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Amidi, Ala
- Contributors dc:contributor
-
- Schneider, Stephen P.
Subjects
dc:subject × 1Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- (MiAaPQ)AAI9989930
- OAI identifier oai:identifier
- oai:www.ideals.illinois.edu:2142/83517