Back to results

University of Illinois at Urbana-Champaign

Accelerated Testing of Separation Layers for Open-Graded Drainage Layers

Abstract

dc:description

An accelerated testing procedure was developed to evaluate performance of separation layers used between open-graded bases and lime stabilized subgrades. Significantly of concern was assessing separation layer performance in regard to the degree of pumping into the open-graded base and the magnitude of deformations occurring during testing. A pneumatically driven, electronically controlled, repeated loading apparatus was designed and constructed to perform the testing of these materials. A low plasticity clay and a silty clay till soil were tested in this research. The separation layers investigated included nonwoven geotextiles and a dense-graded base aggregate blend. Specimens were housed in a stiff wall Plexiglas cylinder during testing. Tests were conducted at various loading levels and durations in order to develop the accelerated testing procedure. Comparisons of specimen deflection and pumping relative to non-separated test cases were made to determine the relative performance of the separation layers and the effect of different loading conditions. Ultimately, loading at levels upwards of 5 times that expected in the field, for short durations (20,000 cycles or less) was performed to evaluate separation layer performance. Separation layer performance under these conditions can be compared to typical loading level performance provided relative measurements are used and it is understood that the failure mechanisms may be different. Geotextiles consistently provided separation between the soils and open-graded aggregates though pumping of fines occurred. The dense-graded separation layer showed a marked drop-off in performance upon wetting of the material. Though the dense-graded layer often prevented the soil layer from intruding into the open-graded layer, the dense-graded layer itself intermixed into the open-graded layer. A distinct breakpoint in performance occurred at a soil strength of CBR 4 under accelerated testing. Soils below CBR 4 showed considerable pumping and deformation regardless of separation layer type. Based upon performance comparisons with non-separated test cases, the use of a separation layer between lime stabilized subgrades and open-graded aggregate bases is imperative.

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Civil Engineering
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Signore, James Michael
Contributors dc:contributor
  • Dempsey, Barry J.

Subjects

dc:subject × 1

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
(MiAaPQ)AAI9904588
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/83460

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Signore, James Michael. Accelerated Testing of Separation Layers for Open-Graded Drainage Layers. Dissertation thesis, University of Illinois at Urbana-Champaign, 2015. http://hdl.handle.net/2142/83460