Abstract
dc:descriptionA series of 2-, 4- and 6-story buildings were designed and evaluated using the proposed method. It was found that 4- and 6-story buildings design and configured based on current provisions using an R factor of 4 did not satisfy the design objective. This resulted mainly from excessive drift demands in the top stories. The buildings were redesigned using an R of 3 and an R of 2, but the buildings were still inadequate. To reduce the excessive drift demand in the top story, the original buildings were reconfigured by using the same braces in even numbered stories that were used in the story below. This resulted in buildings that satisfied the design objective in all cases. Next, the original buildings were reconfigured by making only the top stories stiffer and stronger. These buildings also satisfied the design objectives. Major observations and conclusions are given. Recommendations for future research are presented.