This paper presents analysis of location of refrigerant inventory and numerical results of charge reduction in a typical bottle cooler. The original unit was first characterized by determining its capacity, the coefficient of performance (COP), pull-down characteristics, and total charge using non-intrusive instrumentation. Then the unit was instrumented by insertion of valves to separate main components and allow measurement of the charge in each of them, as well as pressure transducers, a mass flow meter, and thermocouples. Charge optimization and charge distribution experiments were conducted. The condenser is found to be the component that retains the most charge. The system was modeled using Engineering Equation Solver (EES) for calculation of performance and charge. Models were fully validated by experimental results at steady state. Different void fraction correlations were analyzed and utilized to predict charge distributions in heat exchangers. Discussion of the results and recommendation for charge reduction is provided. With the aim of reducing charge without penalizing system performance significantly, the tubes of the round-tube finless condenser were flattened. Charge optimization and charge distribution experiments were again conducted for the system with a flattened-tube condenser. Experimental results show good match with the model prediction.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Jiang, Lingyan
Contributors dc:contributor
  • Hrnjak, Predrag

Subjects

dc:subject × 3

Rights

dc:rights
Statement dc:rights
  • Copyright 2014 Lingyan Jiang
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/72846
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/72846

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation