Back to results

University of Illinois at Urbana-Champaign

Potential of controlling subcooling in residential air conditioning system

Abstract

dc:description

This work presents an experimental and simulation study of one way of improving residential air-conditioning (RAC) system performance by controlling subcooling. Instead of conventional superheat control at evaporator outlet, condenser subcooling is monitored and controlled and the corresponding effects on vapor-compression system performance as well as the sensitivity of subcooling control to different operating conditions and different condenser sizes are discussed. Both experimental and simulation study indicate that there is COP maximizing subcooling due to trade-off of increasing cooling effect and increasing specific compression work as condenser subcooling increases. In the experimental investigation, the potential of performance improvement (COP and cooling capacity Q) by controlling subcooling using EXV is quantified and compared to superheat controlled TXV system. The maximum of 33.0% COP improvement and 14.7% capacity gain is achieved at the same optimum subcooling, benefited from both subcooling control and improved evaporator effectiveness. It is also found that COP maximizing subcooling is a function of ambient temperature T_cai: COP maximizing subcooling temperature increases with increasing ambient temperature. In the simulation investigation, the potential of performance improvement by controlling subcooling is also identified. Both COP and Q maximizing subcooling increase with increasing T_cai. In addition, the effect of condenser size on subcooling controlled system performance is evaluated and the results indicated that smaller size of condenser is more sensitive to change of condenser subcooling. COP or Q maximizing subcooling decreases with increasing condenser size. Combining the simulation and experimental results, subcooling effect and condenser size effect are both interpreted as effects of condenser air refrigerant temperature difference ∆Tin and attempts are made to quantify the linear relationship between ∆Tin and COP (or Q) maximizing subcooling ∆Tsub. With the correlations of COP and Q maximizing subcooling, a control strategy using EXV (electronic expansion valve) with ∆Tin as input signal for controlling subcooling (adjusting the EXV opening) is proposed to provide COP or cooling capacity Q maximizing subcooling for the RAC system as conditions change.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Mechanical Engineering
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2015

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Xu, Lihan
Contributors dc:contributor
  • Hrnjak, Predrag S.

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Copyright 2014 Lihan Xu
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/72818
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/72818

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Xu, Lihan. Potential of controlling subcooling in residential air conditioning system. Thesis thesis, University of Illinois at Urbana-Champaign, 2015. http://hdl.handle.net/2142/72818