University of Illinois at Urbana-Champaign
Low-Energy Photon Dose Deposition in Tissue Slab and Spherical Phantoms
Abstract
dc:descriptionMonte Carlo computer codes were employed to calculate depth doses for parallel beams of low-energy, monoenergetic photons incident on slab and spherical phantoms. Photon energies ranged from 10 to 150 keV. Phantom compositions include: ICRU 4-element tissue, ICRU 10-element tissue, a tissue-substitute plastic, lucite, water, and polystyrene. Tabular data are presented for 0.007, 0.3 and 1.0 g/cm('2) depths. Results are compared with calculations of other workers and with experimental data available for the tissue-substitute plastic.
Degree
thesis:*- Name thesis:degree_name
- Ph.D.
- Level thesis:degree_level
- Dissertation
- Discipline thesis:degree_discipline
- Nuclear Engineering
- Grantor
- University of Illinois at Urbana-Champaign
- Date dc:date
- 10000-01-01
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Nelson, Richard Frederick
Subjects
dc:subject × 1Identifiers
dc:identifier.*- Identifier
- (UMI)AAI8409817
- OAI identifier oai:identifier
- oai:www.ideals.illinois.edu:2142/70890