University of Illinois at Urbana-Champaign
Horizontal Two-Phase Flow of Air-Water Mixtures in Small Diameter Tubes and Compact Heat Exchangers
Abstract
dc:descriptionThe two-phase flow of air-water mixtures in horizontal pipes was studied in order to determine whether pipe diameter is a significant variable in two-phase flow. Also, the flow patterns that exist in a Compact Heat Exchanger were determined in order to verify or refute the assumption that the flow pattern that exists in the Compact Heat Exchanger is an intimate mixture of the two phases with both the gas and the liquid travelling at the same velocity. This is called the 'Homogeneous' flow assumption. It was found that pipe diameter plays a role in horizontal two-phase flow of air-water mixtures through small diameter tubes. Further, the flow patterns that exist in the Compact Heat Exchanger were found to be annular, intermittent and bubble flow. Other flow patterns which can exist in pipes were absent in the Compact Heat Exchanger.
Degree
thesis:*- Name thesis:degree_name
- Ph.D.
- Level thesis:degree_level
- Dissertation
- Discipline thesis:degree_discipline
- Chemical Engineering
- Grantor
- University of Illinois at Urbana-Champaign
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Damianides, Charalambos
- Contributors dc:contributor
-
- Westwater, J.W.,
Subjects
dc:subject × 1Identifiers
dc:identifier.*- Identifier
- (UMI)AAI8803011
- OAI identifier oai:identifier
- oai:www.ideals.illinois.edu:2142/69783