Abstract
dc:descriptionThe effect of heater diameter on the pool and flow boiling heat transfer of saturated Freon-113 was examined. The heaters were horizontal copper tubes of diameter 1.59 to 7.94 mm (pool) and 3.18 to 12.7 mm (flow), heated internally by condensing steam. The test fluid, at atmospheric pressure, flowed upward normal to the heaters, at approach velocities of 2.4, 4.0, and 6.0 m/s.