Scaling and Performance of a Device for Fluidized Bed Entrainment Reduction
Abstract
dc:descriptionA device recently proposed for entrainment suppression from a fluidized bed has been studied. Particles projected upward at the bed surface entered a particle diverter which returned them to the bed. Relations were proposed for scaling the particle mass flux field above the device. Experimental studies were done on two geometrically similar flow systems, using fluidized beds with diameters of 9.5 cm and 33.3 cm. Measurements were made of the particulate mass flux and gas velocity in the dilute phase. A probe was developed which determined the particle mass flux by counting electrical pulses produced when particles collided with a metal sensor placed in the flow stream. Air velocity was measured with a rugged hot film anemometer.
Degree
thesis:*- Name thesis:degree_name
- Ph.D.
- Level thesis:degree_level
- Dissertation
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Grantor
- University of Illinois at Urbana-Champaign
- Year dc:date
- 2014
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Saunders, James Henry, Jr.
Subjects
dc:subject × 2Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- (UMI)AAI8026586
- OAI identifier oai:identifier
- oai:www.ideals.illinois.edu:2142/67025