A liposome-based ion release impedance sensor for HIV detection at the point-of-care

Abstract

dc:description

Many individuals living in remote and resource-limited regions around the world face a barrier to adequate medical care due to the unavailability of diagnostic instrumentation to perform standard measurements which diagnose disease and inform treatment. Factors which limit the availability of diagnostics include both the costs of instrumentation and per-test costs, inadequate portability, the requirement for a laboratory facility, the time required to perform the test, and a need for highly-trained personnel to operate the instrumentation. While a wide variety of approaches primarily based on innovations in micro- and nanotechnology have been reported toward the point-of-care sensing of biological entities, none has yet emerged as a comprehensive solution to the fundamental problems of diagnostic testing in resource-limited settings. In strides toward a platform for low-cost, rapid, easy-to-use point-of-care diagnostics, we present an ELISA-inspired lab-on-a-chip strategy for biological detection based on liposome tagging and ion-release impedance spectroscopy. Ion-encapsulating dipalmitoylphosphatidylcholine (DPPC) liposomes can be functionalized with antibodies and are stable in deionized water yet become permeable for ion release upon heating, making them ideal reporters for electrical biosensing of surface-immobilized antigens. We demonstrate the quantification of these liposomes by real-time impedance measurements and the detection of HIV, which we have selected as a problem to target in the development of this platform, which ultimately can be applied more broadly to other biomolecules and antigens. By showing the detection of viruses on this biosensor platform, we have demonstrate a proof-of-concept which will be further optimized and advanced toward quantitative determination of viral load from whole blood specimens.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Bioengineering
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2013

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Damhorst, Gregory L.
Contributors dc:contributor
  • Bashir, Rashid

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Copyright 2013 Gregory Lawrence Damhorst
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/44806
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/44806

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Damhorst, Gregory L.. A liposome-based ion release impedance sensor for HIV detection at the point-of-care. Thesis thesis, University of Illinois at Urbana-Champaign, 2013. http://hdl.handle.net/2142/44806