Back to results

University of Illinois at Urbana-Champaign

Determination of hydrogen peroxide using immobilized chemiluminescence reagents and flow injection analysis

Abstract

dc:description

In this work, use of immobilized luminol for the CL determination of hydrogen peroxide using flow injection analysis (FIA) was investigated. Nylon was initially chosen as the immobilization support because of its chemical inertness. Luminol was covalently immobilized on the inside of nylon tubing and used for FIA determination of peroxide using solution-phase hemin as catalyst (detection limit = 0.4 μM, relative standard deviation (rsd) = 2.5%). Next, horseradish peroxidase (HRP) was immobilized on nylon membranes. Luminol was immobilized on to an anion exchange resin and packed in a column. When used in the FIA mode, stoichiometric amounts of luminol could be released from the column by injecting another anion with higher affinity towards the resin. The pH downstream of the column could also be controlled by the amount of anion injected upstream of the column. Such columns were used in a single channel FIA scheme for the determination of peroxide in conjunction with immobilized HRP as catalyst (detection limit = 8 μM, mean rsd = 0.8%). The experiment was extended for the determination of glucose by using co-immobilized HRP and glucose oxidase (detection limit = 25 μM). The problem presented by real samples was solved using a sample pre-treatment technique.

Degree

thesis:*
Name thesis:degree_name
Ph.D.
Level thesis:degree_level
Dissertation
Discipline thesis:degree_discipline
Chemistry
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2011

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rao, Narasimha Murthy
Contributors dc:contributor
  • Nieman, Timothy A.

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright 1990 Rao, Narasimha Murthy
Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
AAI9114378
(UMI)AAI9114378
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/20998

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Rao, Narasimha Murthy. Determination of hydrogen peroxide using immobilized chemiluminescence reagents and flow injection analysis. Dissertation thesis, University of Illinois at Urbana-Champaign, 2011. http://hdl.handle.net/2142/20998