University of Illinois at Urbana-Champaign
The effect of drop concentration on deposition in vertical annular two-phase flow
Abstract
dc:descriptionDeposition in annular two phase flow has been found to deviate from a linear rate law. At high liquid flows the rate constant is found to vary inversely with drop concentration (i.e. the rate of deposition is independent of concentration). This deviation causes concern when predicting dryout in two phase applications. To better understand this process, information on its drop size and on the behavior of drops in the turbulent gas flow are needed. Experiments were conducted in a 4.2 cm vertical pipe at an upward superficial gas velocity of 36 m/s and at liquid mass flow rates from 30 to 170 g/s. Photographic drop size measurements were obtained. Measurements of entrainment, gas velocity, slip ratio, and drop concentration were also obtained. An increase in mean drop diameters with increasing drop concentration was found.
Degree
thesis:*- Name thesis:degree_name
- Ph.D.
- Level thesis:degree_level
- Dissertation
- Discipline thesis:degree_discipline
- Chemical Engineering
- Grantor
- University of Illinois at Urbana-Champaign
- Year dc:date
- 2011
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Hay, Kent James
- Contributors dc:contributor
-
- Hanratty, Thomas J.
Subjects
dc:subject × 1Rights
dc:rights- Statement dc:rights
-
- Copyright 1994 Hay, Kent James
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
-
AAI9512390
(UMI)AAI9512390 - OAI identifier oai:identifier
- oai:www.ideals.illinois.edu:2142/20554