University of Illinois Urbana-Champaign
Thermal design and solutions for handling heat loads in high-speed connectors for data centers
Abstract
dc:descriptionThe rapid growth of data transmission and power density in high-speed interconnects such as OSFP (Octal Small Form-Factor Pluggable) and QSFP (Quad Small Form-Factor Pluggable) modules have made thermal management a critical design challenge. Although liquid cooling has emerged as a high-capacity alternative, its implementation at the connector level remains challenging due to system complexity, elevated cost, and potential reliability concerns. Consequently, this study focuses on enhancing air-cooled forced convection performance using computational fluid dynamics (CFD) based modeling and experimental validation. A detailed 3-D numerical model was developed in Ansys Icepak Classic 2023 to simulate conjugate heat transfer within high-speed connector assemblies under realistic airflow and thermal conditions. The model accounted for conduction, convection, and fan-driven pressure differences corresponding to 3 inWC (≈ 746.5 Pa) system airflow. Multiple configurations, varying dividing floor geometry (solid vs. perforated), heat-sink placement (top, bottom, and inter-module), and cage ventilation (standard vs. vented), were examined for both OSFP 2×1 and QSFP 1×1 architectures. Model validation against experimental measurements demonstrated excellent agreement, with an error margin below ±5%. The results revealed that introducing a perforated dividing floor enhanced inter-module airflow mixing, lowering hotspot temperatures by 3-4 °C, while adding a bottom heat sink achieved an additional 6-8 °C reduction and decreased junction-to-ambient thermal resistance by approximately 13%. Relocating the bottom heat sink to an inter-module riding configuration improved temperature uniformity without compromising structural integrity and incorporating side and bottom cage vents provided a further 5-7 °C reduction through improved airflow distribution. For the QSFP 1×1 model, a vapor-chamber heat sink outperformed a traditional zipper-fin design, reducing peak temperature by 5-6 °C under 44 W load conditions. This research demonstrates that optimized air-cooling architectures can effectively manage thermal loads in high-power-density connector systems without transitioning to liquid cooling. The validated CFD framework offers a robust tool for future design optimization, transient analysis, and system-level integration of connector-cooling technologies in data-center applications.
Degree
thesis:*- Name thesis:degree_name
- M.S.
- Level thesis:degree_level
- Thesis
- Discipline thesis:degree_discipline
- Mechanical Engineering
- Grantor
- University of Illinois Urbana-Champaign
- Year dc:date
- 2025
Author and committee
dc:creator, dc:contributor.*- Author dc:creator
-
- Maruf, Tayfur Rahman
- Contributors dc:contributor
-
- Miljkovic, Nenad
Subjects
dc:subject × 8Rights
dc:rights- Statement dc:rights
-
- Copyright 2025 Tayfur Rahman Maruf
- Language dc:language
- en
Identifiers
dc:identifier.*- Handle dc:identifier
- https://hdl.handle.net/2142/132644
- OAI identifier oai:identifier
- oai:www.ideals.illinois.edu:2142/132644