Data center cooling using Aquifer Thermal Energy Storage (ATES)

Abstract

dc:description

Data centers have become critical infrastructure in the rapidly-expanding digital economy, supporting cloud computing, artificial intelligence (AI), and high-performance computing. They are rapidly becoming major electricity consumers, and nearly 40% of their demand comes from cooling alone, underscoring the need for more energy-efficient and sustainable cooling methods. This thesis develops a comparative techno- economic framework to evaluate two advanced cooling strategies. Magnetic bearing chillers (MBC) and MBC + aquifer thermal energy storage (ATES) against a conventional water-cooled centrifugal chiller plant with CRAH units for mid-sized data centers. Hourly cooling-energy and cost simulations were performed for the City of Phoenix, Arizona, and the City of Fairbanks, Alaska, under identical IT loads and setpoints. Performance was assessed through annual cooling energy, energy cost, peak electrical demand, cooling-only PUE′ (average and 95th percentile), and economic indicators including incremental NPV, IRR, and SPB, all evaluated relative to the baseline centrifugal-chiller + CRAH configuration. Results show that MBC reduce the energy needed for cooling annually, by up to 28% with peak electrical demand of approximately 34kW (7.2%) in the City of Phoenix, improving the average PUE′ from 1.20 - 1.14 and achieving a 2.2-year payback with an IRR of 47.9 %. The integration of ATES further lowers lifecycle costs, yielding an NPV of $1.5M and a 5.2-year payback, while maintaining similar energy performance. In the City of Fairbanks, absolute savings are smaller due to extensive free-cooling hours; however, the hybrid MBC + ATES configuration still delivers a 17% reduction in the cost of energy and long-term financial viability (IRR 10.2 %). For both cities, the cost of electricity comprises the majority of operating expenses (>95%), making tariff structure and climate the primary determinants of financial viability. Overall, based on the literature review, this study concludes that the MBC and ATES-integrated cooling approaches not only improve economic performance but also reduce Scope 2 emissions by lowering mechanical cooling demand, aligning with trends reported in prior work.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Industrial Engineering
Grantor
University of Illinois Urbana-Champaign
Year dc:date
2025

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Malpure, Apurva
Contributors dc:contributor
  • Sreenivas, Ramavarapu
  • Stumpf, Andrew

Subjects

dc:subject × 5

Rights

dc:rights
Statement dc:rights
  • © 2025 Apurva Malpure
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
https://hdl.handle.net/2142/132585
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/132585

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Malpure, Apurva. Data center cooling using Aquifer Thermal Energy Storage (ATES). Thesis thesis, University of Illinois Urbana-Champaign, 2025. https://hdl.handle.net/2142/132585