Back to results

University of Illinois at Urbana-Champaign

Safety and data quality of EEG recorded simultaneously with multi-band fMRI

Abstract

dc:description

Simultaneously recorded electroencephalography and functional magnetic resonance imaging (EEG-fMRI) is highly informative yet technically challenging. Until recently, there has been little information about EEG data quality and safety when used with newer multi-band (MB) fMRI sequences. Here, we measure the relative heating of a MB protocol compared with a standard single-band (SB) protocol considered to be safe. We also evaluated EEG quality recorded concurrently with the MB protocol on humans. We compared radiofrequency (RF)-related heating at multiple electrodes and magnetic field magnitude, B_(1+RMS), of a MB fMRI sequence with whole-brain coverage (TR = 440 ms, MB factor = 4) against a previously recommended, safe SB sequence using a phantom outfitted with a 64-channel EEG cap. Next, 9 human subjects underwent eyes-closed resting state EEG-fMRI using the MB sequence. Additionally, in three of the subjects resting state EEG was recorded also during the SB sequence and in an fMRI-free condition to directly compare EEG data quality across scanning conditions. EEG data quality was assessed by the ability to remove gradient and cardioballistic artifacts along with a clean spectrogram. The heating induced by the MB sequence was lower than that of the SB sequence by a factor of 0.73 ± 0.38. This is consistent with an expected heating ratio of 0.64, calculated from the square of the ratio of B_(1+RMS) values of the sequences. In the resting state EEG data, gradient and cardioballistic artifacts were successfully removed using traditional template subtraction. All subjects showed an individual alpha peak in the spectrogram with a posterior topography characteristic of eyes-closed EEG. The success of artifact rejection for the MB sequence was comparable to that in traditional SB sequences. Our study shows that B_(1+RMS) is a useful indication of the relative heating of fMRI protocols. This observation indicates that simultaneous EEG-fMRI recordings using this MB sequence can be safe in terms of RF-related heating, and that EEG data recorded using this sequence is of acceptable quality after traditional artifact removal techniques.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Psychology
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Egan, Maximillian Kirichenko
Contributors dc:contributor
  • Sadaghiani, Sepideh

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Copyright 2021 Maximillian Egan
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/110606
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/110606

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Egan, Maximillian Kirichenko. Safety and data quality of EEG recorded simultaneously with multi-band fMRI. Thesis thesis, University of Illinois at Urbana-Champaign, 2021. http://hdl.handle.net/2142/110606