Back to results

University of Illinois at Urbana-Champaign

Model-based myelin water fraction mapping: analyses and improvement

Abstract

dc:description

In this thesis, the problem of model-based myelin water fraction (MWF) mapping is addressed. We first focus on three of the most widely used signal models for T2*-myelin water imaging (MWI), i.e., the NNLS-multi-exponential model, the magnitude-3-exponential model, and the complex-3-exponential model, and investigate their sensitivities to practical perturbations such as random noise and field-related structured errors. We demonstrate through both Cramér-Rao lower bound (CRLB) analyses and Monte Carlo simulations that the three signal models are all very unstable inherently. Comparatively speaking, however, we demonstrate the theoretical advantage of the 3-exponential models over the multi-exponential model in handling noise, and the practical advantage of the magnitude models over the complex model in handling phase-related perturbations for T2*-MWI. We also illustrate the necessity and effects of incorporating various types of constraints for additional sensitivity gain. Using the insights obtained in the sensitivity analyses, we then propose a new MWF fitting scheme that leverages an improved signal model and a set of more effective constraints. In particular, a relaxed magnitude-3-exponential model with additional frequency compensation terms is introduced to better represent voxels with large field variations; a set of statistical distributions learned from in vivo training data is further imposed on the model parameters for additional constraints. Using phantom simulation and in vivo experiments, we then evaluate and compare the proposed method with several popular conventional MWF fitting schemes to demonstrate the improved accuracy and robustness of the proposed method. In this thesis, a literature review on the study of myelin and the development of MWF mapping is provided at the start of the work. Background materials on the CRLB theories are also provided to facilitate reading.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Electrical & Computer Engr
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Xiong, Jiahui
Contributors dc:contributor
  • Liang, Zhi-Pei

Subjects

dc:subject × 4

Rights

dc:rights
Statement dc:rights
  • Copyright 2020 Jiahui Xiong
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/109583
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/109583

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Xiong, Jiahui. Model-based myelin water fraction mapping: analyses and improvement. Thesis thesis, University of Illinois at Urbana-Champaign, 2021. http://hdl.handle.net/2142/109583