dc:description

A fundamental problem in X-ray Computed Tomography (CT) is the scatter occurring due to the interaction of photons with the imaged object. Unless it is corrected, this phenomenon manifests itself as degradations in the reconstructions in the form of various artifacts. This makes scatter correction a critical step to obtain the desired reconstruction quality. Scatter correction methods consist of two groups: hardware-based and software-based. Despite success in specific settings, hardware-based methods require modification in the hardware or an increase in the scan time or dose. This makes software-based methods attractive. In this context, Monte-Carlo based scatter estimation, analytical-numerical and kernel-based methods were developed. Furthermore, the capacity of data-driven approaches to tackle this problem was recently demonstrated. In this thesis, two novel physics-motivated deep-learning-based methods are proposed. The methods estimate and correct for the scatter in the obtained projection measurements. They incorporate both an initial reconstruction of the object of interest and the scatter-corrupted measurements related to it. They use a common specific deep neural network architecture and a cost function adapted to the problem. Numerical experiments with data obtained by Monte-Carlo simulations of the imaging of phantoms reveal noticeable improvement over a recent projection-domain deep neural network correction method.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Electrical & Computer Engr
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Iskender, Berk
Contributors dc:contributor
  • Bresler, Yoram

Subjects

dc:subject × 7

Rights

dc:rights
Statement dc:rights
  • Copyright 2020 Berk Iskender
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/109445
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/109445

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Iskender, Berk. X-ray CT scatter correction by a physics-motivated deep neural network. Thesis thesis, University of Illinois at Urbana-Champaign, 2021. http://hdl.handle.net/2142/109445