Back to results

University of Illinois at Urbana-Champaign

Design and development of robotic system for endovascular procedures

Abstract

dc:description

Endovascular surgeries are highly preferred minimally invasive procedures performed through blood vessels for diagnostic and therapeutic purposes. In conventional open surgery, surgeons have complete control on the surgical tool, but in the case of endovascular procedures, a highly flexible tool, which is operated from distal end provides an indirect control. Moreover, the operating end of these flexible tools inside a patient are controlled from distal end, outside patient's body, with an imperceptible force feedback from the tool. Even though fluoroscopic images like X-rays provide a temporary solution, the perceptive of depth is not available in these visual feedback and the prolonged hazardous radiations do not provide a safer working environment for surgeons. A tele-operated robotic systems have enhanced the surgical conditions nevertheless, it decline to provide a better system which can help surgeons to use their intuitive surgical skills. Additionally, these robotic system requires replacement of the low cost conventional surgical tools with expensive one, thus increasing the procedural cost. This thesis work addresses these two issues in the endovascular robotic systems by 1. Developing an intuitive user interface console to help ease of transfer of surgical skills for surgeons, 2. Developing an in-built force feedback sensing mechanism in the robot that is adaptable to conventional surgical tool. A new interventional robotic system (IRS) with teleoperation control was developed to isolating the surgeons from hazardous radiation. The master console of IRS is design to capture surgeon’s conventional surgical gestures thus, eliminating the need for learning new skills to manipulate surgical robots. IRS ensures patient’s safety by providing haptic feedback to surgeons using reactive force experienced by surgical tool. IRS also has the adaptability to use the conventional surgical tool of wide range of dimensions. Finally, the force measurement evaluation and performance assessment of the IRS were presented. The future scopes of this research work are briefly discussed.

Degree

thesis:*
Name thesis:degree_name
M.S.
Level thesis:degree_level
Thesis
Discipline thesis:degree_discipline
Systems & Entrepreneurial Engr
Grantor
University of Illinois at Urbana-Champaign
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Sankaran, Naveen Kumar
Contributors dc:contributor
  • Kesavadas, Thenkurussi

Subjects

dc:subject × 1

Rights

dc:rights
Statement dc:rights
  • Copyright 2016 Naveen Sankaran
Language dc:language
en

Identifiers

dc:identifier.*
Handle dc:identifier
http://hdl.handle.net/2142/100412
OAI identifier oai:identifier
oai:www.ideals.illinois.edu:2142/100412

Chain of custody

source
Harvested from
University of Illinois - Urbana-Champaign
Base URL
www.ideals.illinois.edu/oai-pmh
Last updated
2026-07-22
Source record
OAI-PMH GetRecord
citation

Sankaran, Naveen Kumar. Design and development of robotic system for endovascular procedures. Thesis thesis, University of Illinois at Urbana-Champaign, 2018. http://hdl.handle.net/2142/100412