Back to results

University of Toronto

Microfluidic Interfaces for Mass Spectrometry: Methods and Applications

Abstract

dc:description.abstract

Since the introduction of electrospray ionization (ESI) and matrix assisted laser desorption ionization (MALDI), there has been an unprecedented growth of biomolecule analysis using mass spectrometry (MS). One of the most popular applications for mass spectrometry is the field of proteomics, which has emerged as the next scientific challenge in the post-genome era. One critical step in proteomic analysis is sample preparation, a major bottleneck that is attributed to many time consuming and labor-intensive steps involved. Microfluidics can play an important role in proteome sample preparation due to its ability to handle small volumes of sample and reagent, and its capability to integrate multiple processes on a single chip with the potential for high-throughput analysis. However, to utilize microfluidic systems for proteome analysis, an efficient interface between microfluidic chip and mass spectrometry is required. This thesis presents several methods for coupling of microfluidic chips with ESI-MS and MALDIMS. III Three microfluidic-ESI interfaces were developed. The first interface involves fabricating a polymer based microchannel at the rectangular corners of the glass substrates using a single photolithography step. The second interface was build upon the previous interface in which a digital microfluidic platform was integrated with the microchannel in a “top-down” format. The integrated microfluidic system was used for inline quantification of amino acids in dried blood spots that have been processed by digital microfluidics. The third interface was formed by sandwiching a pulled glass capillary emitter between two digital microfluidic substrates. This method is a simpler and more direct coupling of digital microfluidics with ESI-MS as compared to the method used for second interface. Finally, a strategy using a removable plastic “skin” was developed to interface digital microfluidics with MALDI-MS for offline sample analysis. We demonstrated the utility of this format by implementing on-chip protein digestion on immobilized enzyme depots.

Degree

thesis:*
Department dc:contributor.department
Chemistry
Year dc:date.issued
2012

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Yang, Hao
Advisor dc:contributor.advisor
  • Wheeler, Aaron

Subjects

dc:subject × 6

Rights

dc:rights
Statement dc:rights
  • Attribution-NonCommercial-NoDerivs 3.0 Unported
Language dc:language.iso
en_ca

Identifiers

dc:identifier.*
Handle dc:identifier.uri
http://hdl.handle.net/1807/31982
OAI identifier oai:identifier
oai:utoronto.scholaris.ca:1807/31982

Chain of custody

source
Harvested from
University of Toronto
Base URL
utoronto.scholaris.ca/server/oai/request
Last updated
2026-07-27
Source record
OAI-PMH GetRecord
citation

Yang, Hao. Microfluidic Interfaces for Mass Spectrometry: Methods and Applications. 2012. http://hdl.handle.net/1807/31982