Back to results

Texas Digital Library

Effects of drop size and drop velocity on cooling characteristics of sprays

Abstract

dc:description.abstract

The effect of drop size and drop velocity on the cooling characteristics of sprays was investigated in this study. Various line pressures and distances from the nozzle were used to obtain Sauter mean drop sizes between 200 and 300 microns, and velocities between 80 and 130 m/s. Local heat flux data were collected using the temperature profile generated in the heated billet as the billet cooled from above 400° C to below 100° C. Experimental results show an increase in heat flux with increasing velocity for local mass fluxes of 34 and 53 g/cm2 s, for both maximum heat flux and for the heat flux at a surface temperature of 300° C. Also, effective heat flux decreased with increasing droplet Sauter mean diameter over the range of test conditions.

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Blount, Erick C.

Subjects

dc:subject × 2

Rights

dc:rights
Statement dc:rights
  • Unrestricted.
Language dc:language
eng

Identifiers

dc:identifier.*
OAI identifier oai:identifier
oai:tdl-ir.tdl.org:2346/59883

Chain of custody

source
Harvested from
Texas Digital Library
Base URL
tdl-ir.tdl.org/server/oai/request
Last updated
2026-07-27
Source record
OAI-PMH GetRecord
citation

Blount, Erick C.. Effects of drop size and drop velocity on cooling characteristics of sprays. 1991. https://hdl.handle.net/2346/59883