Back to results

University of Strathclyde

Design and development of an electrochemical and infrared spectroscopic medical device for serum-based cancer diagnostics

Abstract

dc:description.abstract

Development of an integrated electrochemical and spectroscopic serum diagnosticdevice would have significant potential as a triage tool for brain cancer and Hodgkin’slymphoma in primary care settings to better inform clinical decisions and facilitateprompt referral to secondary care, whilst reducing financial and practical constraintsplaced on current diagnostic modalities. Additionally, the ability to detect IDH1molecular status from serum samples would have significant clinical value to patientsand clinicians alike, ultimately allowing earlier diagnosis and improved planning ofsurgery and treatment therapeutics. To this extent, the medical device hasdemonstrated the ability to electrochemically detect the biomarker CCL17/TARC at387-50,000pg/ml concentrations with R2 = 0.979 and limit of detection of 387pg/mlin spiked buffer samples. Thereafter, the medical device demonstrated successfuldiagnosis of Hodgkin’s lymphoma in all 11 tested clinical patient samples.Additionally, ATR-FTIR discriminated between Hodgkin’s lymphoma and healthycontrols in 200 patient samples with sensitivity of 83.2 ± 6.6% and specificity of 85.3± 8.1% with Random Forest classification, highlighting differences in proteinsecondary structures within clinical serum samples. The integrated diagnostic platformfurther demonstrated the ability to electrochemically detect IDH1-R132H proteins inspiked buffer samples at 0.05-10,000ng/ml concentrations with R2 = 0.958. However,it was not subsequently possible to detect IDH1 mutant proteins in clinical serumsamples. Nevertheless, ATR-FTIR demonstrated the ability to discriminate betweenIDH1 molecular status in 104 glioma patients through consideration of the globalmolecular signatures ofserum samples with sensitivity of 89.0 ± 11.3% and specificityof 88.2 ± 10.1% with PLS classification.

Degree

thesis:*
Name dc:type.qualificationname
engd
Level dc:type.qualificationlevel
doctoral-pg
Grantor dc:publisher.institution
University of Strathclyde
Year dc:date.issued
2020

Author and committee

dc:creator, dc:contributor.*
Author dc:creator
  • Rinaldi, Christopher
Advisors dc:contributor.advisor
  • Baker, Matthew
  • Dennany, Lynn

Identifiers

dc:identifier.*
Identifier
T15633
Author Identifier
201559983
OAI identifier oai:identifier
oai:strathclyde:2j62s4901

Chain of custody

source
Harvested from
University of Strathclyde
Base URL
stax.strath.ac.uk/catalog/oai
Last updated
2026-07-24
Source record
OAI-PMH GetRecord
related terms
citation

Rinaldi, Christopher. Design and development of an electrochemical and infrared spectroscopic medical device for serum-based cancer diagnostics. doctoral-pg thesis, University of Strathclyde, 2020. https://stax.strath.ac.uk/concern/theses/2j62s4901